Maintenance and diagnostic tests – HP 1Gb/2Gb switch 16B A7340-96002 User Manual

Page 38

Advertising
background image

32

Quick Start Guide

Maintenance and Diagnostic Tests

The FC 16B does not require any regular physical maintenance, and is
designed to minimize the chance of failure, including diagnostic tests and
field-replaceable units.

Diagnostic tests are provided to help troubleshoot the hardware and the
firmware. The diagnostic tests provided on the switch include tests of
internal connections and circuitry, fixed media, and any SFP modules and
fiber optic cables in use. The tests are implemented by command, either
through a telnet session or through a terminal set up for a serial connection
to the switch. Some tests require the ports to be connected by external
cables, to allow diagnostics to verify the serializer/deserializer interface, as
well as the attached SFP and cable.

All diagnostic tests are run at link speeds of both 1 Gbps and 2 Gbps. For
detailed information about the specific diagnostic tests and how to run
them, refer to the Fabric OS Procedures Guide.

Test

Command

Description

Error Log

errDump

Displays the error log without
page breaks.

Switch Offline

switchDisable

Sets the switch to offline state
necessary to run certain switch
diagnostics.

Memory Test

ramTest

Checks CPU RAM memory. Run
offline or online.

Port Register
Test

portRegTest

Checks that the registers and static
memory in each ASIC can be
successfully accessed. Run
offline.

Central Memory
Test

centralMemoryTest

Checks that the central memory in
each ASIC can be successfully
accessed. Run offline.

Control Message
Interface (CMI)
Conn Test

cmiTest

Verifies that control messages can
be sent from ASIC to ASIC.
Run offline.

Advertising