Page 108 quick start guides – Hach 900 MAX User Manual

Page 110

Advertising
background image

Page 108
Quick Start Guides

8990apdx_quickstart.fm

Appendix A

Sigma 900 MAX Refrigerated Sampler Advanced Sampling Flow Chart

Flow Rate of Chg
Rainfall

Options

Setup

Status

Display Data

Main Menu

Modify

Selected

Items

Advanced

Sampling

Program

Complete

Output

Enable /

Disable

Note: Enables pin F for

Program Complete output on

Auxillary connector.

Also disables its use for

Bottle# & Full Bottle Indicator.

Setpoint *

Sampling

Special

Output

Start /

Stop

Times

Storm
Water

Timed

Bottle

Sets

Upset

Sample

Enable /

Disable

Start on

Setpoint

-or-

Start /

Stop on

Setpoint

Set HIGH

trigger and

Deadband

Set LOW

trigger and

Deadband

or

Set High

Trigger

Set

Time

Interval

Enter Delay
When Input

Becomes

Active

External Control

Note: The Special Output

signal is available on pin E of

the Auxiliary connector.

Enable /

Disable

Enable: After Each Sample, Only When

Pumping or From Rinse to Purge

An arrow displayed next to an Advanced Sampling
option in the menu display signifies it is enabled.

Enable /

Disable

Time / Date

Time / Weekday

or

Enter Time and Date for

each start and stop

Enter Time and Day of

Week for each start and stop

Enable /

Disable

Select Start

Condition: Rain,

Level, Rain AND

Level, Rain OR

Level, Immediate

or

External Trigger

Select

# of

First

Flush

Bottles

Select:

Samples/Bottle

or

Bottles/Sample

Enter

Sampling

Interval

Enter

Sample
Volume

Enter

Program

Time Limit

Enable /

Disable

Clock

Time

Note: Timed Bottle is not

allowed unless Bottles-per-

Sample mode is selected in

Distribution Menu.

Duration

Enter Time of next

Bottle Set

Enter Time Interval

till next Bottle Set

or

Enable/

Disable

Continuous

Mode

Enable /

Disable

Flow Rate of Chg
Rainfall

External Control

Set HIGH

Trigger

Set LOW

Trigger

or

Set

HIGH

Trigger

Set

Time

Interval

Enter #

of

Upset

Bottles

Select:

Samples/Bottle

or

Bottles/Sample

Enter Sample

Volume

Level
Flow
pH / ORP
Process Temp
Channel 1
Channel 2
Channel 3
Ch 4 or D.O.
Ch 5 or DO Temp.
Ch 6 or Cond.
Ch 7 or Cond Tmp

Begin with

Bottle 1 on

each New

Start?

* Note: Setpoint Sampling &

Storm Water Cannot

Be Enabled at the Same

Time.

Variable

Intervals

Enable /

Disable

Set

Sample

Intervals

Level
Flow
pH / ORP
Process Temp
Channel 1
Channel 2
Channel 3
Ch4 or D.O.
Ch5 or D.O. Temp
Ch6 or Cond
Ch7 or Cond Temp

Select Only One Channel or
External Control for Setpoint.

Grey box indicates function not available with
CTVV sampling enabled. [Even if function is
still listed in screen menus.]

key: