Chapter 2 – Explanation of Functions

2.4 Torque

bias

The inverter is able to accept an analog voltage signal from a load cell that represents car weight. This

signal is used to adjust the instantaneous starting torque to achieve smooth motion regardless of load.

Motor


LAD

ASR

ACR

Counterweight

HOLD

FW side gain

RV side gain

FW side balance

value110)

RV side balance value

Filter

Measure

Target f

Hold signal

O2

SSD

Changeover according to
the direction

Point A

Point B

Figure 4 – Torque bias circuit diagram

Cabin

Encoder

< Additional setting items>

Function

Code

Function Name

Setting Range

Remarks

A071

Selection of Torque Bias
Input

-

00: O Input
01: OI Input (Note 2)
02: O2 Input (Note 3)

P110

FW side balance value

0.0 - 10.0 (V)

Total weight output at balanced point
(FW direction side)

P111

RV side balance value

0.0 - 10.0 (V)

Total weight output at balanced point
(RV direction side)

P112

FW side gain

0.0 - 200.0 (%)

Torque value to be added in case of
max. weight (FW direction side)

P113

RV side gain

0.0 - 200.0 (%)

Torque value to be added in case of
max. weight (RV direction side)

P114

Time constant of the filter

5 - 500 (ms)

C001

- C008

Intelligent input
terminals 1 - 8

- 50:

SSD

Note 1: Do not configure the same analog input for torque bias input (A071), frequency source setting

(A001), and torque limit input (B040).

Note 2: When OI input is used for torque bias, the ranges of P110 and P111 are still 0 – 10 V, so it will be

necessary to translate the 4 – 20 mA signal value to 0 – 10 V for these parameter settings.

Note 3: When O2 is selected for torque bias, the range is 0 to +10 V. Negative values are ignored.

15