Explanation of functions – Hitachi SJ300 Series User Manual

Page 9

Advertising
background image

Chapter 2 – Explanation of Functions

2.

Explanation of Functions

2.1 S-curve acceleration and deceleration for elevator (EL S-curve)

Output
Frequency

(A)

(B)

(C)

(D)

Dec. time
(F003)

Acc.time
(F002)

time


f-max








Shape of curve portions (A) to (D) above can be adjusted separately, as shown in the following table.

Setting value is a % of target frequency.

<Setting items>

Function

Code

Function Name

Setting Range

Remarks

A097 Acceleration

pattern

selection

Select “04”

A098 Deceleration

pattern

selection

Select “04”

P060

Curve ratio 1 during
acceleration

0. – 50 (%)

Portion (B)

P061

Curve ratio 2 during
acceleration

0. – 50 (%)

Portion (A)

P062

Curve ratio 1 during
deceleration

0. – 50 (%)

Portion (C)

P063

Curve ratio 2 during
deceleration

0. – 50 (%)

Portion (D)

(Note 1) A linear characteristic will result (A097 = A098=00) if 0% is set for the curve ratio.

(Note 2) A linear characteristic will result if the change of the target speed is less than or equal

to 10% of the maximum frequency.

(Note 3) All of the curve constants are ignored if “04” is selected in A097 and A098. Refer to the

manual for standard S-curve acceleration & deceleration description.

(Note 4) The S-curve will be recalculated if the target speed is changed while accelerating or

decelerating. Therefore do not use analog signals for the target speed.

(Note 5) Curve ratio for acceleration/deceleration must be in the range of 10% up to 50%.

9