< Total weight output and items to be set >

Torque to be added (%)

< Additional setting items>

Function

Code

Function Name

d107

Point A (FW deviation) monitor

d108

Point B (RV deviation) monitor

Total weight output (V)

Gain

(FW/RV side)

0

Regen.

Balanced point

Power

V1: Balance value

10

If 10V

≥ total weight output Æ converted value to 10V

200

Figure 5 – Balance Point

< How to adjust >

Bias weight adjustment and gain adjustment of the analog weight signal are required when using the
torque bias function.

c Bias weight adjustment (Balance adjustment)

Put weight in the elevator car to balance it with the counterweight. Then adjust the following parameters to
make the deviation values at points A (d107) and B (d108) 0 (zero).

Balance value (P110, P111) =

[%]

]

[

]

[

100

V

10

V

V

1

1

×

⎟⎟

⎜⎜

V1 : Voltage when the car and counterweight are balanced (see Figure 5).

d

Gain adjustment

Gain =

]

[

]

[

]

[

.

V

V

V

V

V

10

82

1

100

1

2

Ч

Ч

α

α

: Torque bias value (%) at maximum load weight

V1: Voltage when the car and counterweight are balanced
V2: output voltage of the sensor at maximum load weight

2.5 Battery backup function

This custom function allows emergency operation at low speed via an external battery or UPS system in

case of main AC power failure. This feature is NOT standard. Please contact Hitachi representatives with

16