remarks

A092 Acceleration

time2

0.01-99.99/100.0-999.9/1000.-3600.(s)

15.00

A093 Deceleration

time2

0.01-99.99/100.0-999.9/1000.-3600.(s)

15.00

A094 2

nd

stage adjustable selection

00(change with 2CH terminal)/01(change with setting)

00

*A095 2

nd

acceleration frequency

0.00-99.99/100.0-400.0(Hz)

0.00

*A096 2

nd

deceleration frequency

0.00-99.99/100.0-400.0(Hz)

0.00

A097 Acceleration

pattern

selection

00(straight line)/01(S-curve)/02(U-curve)/03(reverse U-curve)/

04(EL-S curve)

04

A098 Deceleration

pattern

selection

00(straight line)/01(S-curve)/02(U-curve)/03(reverse U-curve)/

04(EL-S curve)

04

*A101 OI

start

frequency

0.00-99.99/100.0-400.0(Hz)

0.00

*A102 OI

end

frequency

0.00-99.99/100.0-400.0(Hz)

0.00

A103

OI start current

0.-100. (%)

20.

A104

OI end current

0.-100. (%)

100.

A105

OI start selection

00(external start frequency)/01(0Hz)

01

*A111 O2

start

frequency

0.00-99.99/100.0-400.0(Hz)

0.00

*A112 O2

end

frequency

0.00-99.99/100.0-400.0(Hz)

0.00

A113

O2 start voltage

0.-100. (%)

-100%


A114

O2 end voltage

0.-100. (%)

100%

A131

Acceleration curve constant

01(small swelling)-10(large swelling)

01

A132

Deceleration curve constant

01(small swelling-10(large swelling)

01

b001 Retry

selection

00(trip)/01(0Hz start)/02(start after equal frequency)/

03(trip after equaling frequency and deceleration stop)

00

b002

Allowable under-voltage power
failure time

0.3-1.0(s) 0.3

b003 Retry

wait

time

0.3-100.(s)

1.0

b004

Instantaneous power failure/
under-voltage trip during stop

00(invalid/01(valid)/02(invalid during stop and deceleration by stop

command)

01

b005

Instantaneous power failure/
under-voltage retry time
selection

00(16 times)/01(free)

00

b006 Open-phase

selection

00(invalid)/01(valid)

00

*b007

Frequency setting to match

0.00-99.99/100.0-400.0(Hz)

0.00

b012

Electronic thermal level

0.2*constant current-1.20*constant current (A)

Rated
Current of
inverter

b013

1

st

electronic thermal

characteristic selection

00(reduced characteristic)/ 01(constant torque characteristic)/

02(free setting)

01

*b015

Free electronic thermal frequency
1

0.-400.(Hz) 0.

b016

Free electronic thermal current
1

0.0-1000.(A) 0.0

*b017

Free electronic thermal frequency
2

0.-400.(Hz) 0.

b018

Free electronic thermal current
2

0.0-1000. (A)

0.0

*b019

Free electronic thermal frequency
3

0.-400.(Hz) 0.

b020

Free electronic thermal current
3

0.0-1000.(A) 0.0

b021

Overload restriction selection

00(invalid)/01(enabled on acceleration / constant speed)/

02(enabled on constant speed)/03(enabled on acceleration / constant speed

(speed increasing at regenerating mode))

01

b022

Overload restriction level

0.50* rated current-2.00* rated current(A)

Rated

current

of

Inverter

x 1.50

b023

Overload restriction limit constant

0.10-30.00(s)

1.00

b024

Overload restriction 2 selection

00(invalid)/01(enabled on acceleration / constant speed)/

02(enabled on constant speed)/03(enabled on acceleration / constant speed

(speed increasing at regenerating mode))

01

b025

Overload restriction level 2

0.50*rated current-2.00*rated current(A)

Rated

current

of

Inverter

x 1.50

b026

Overload restriction constant 2

0.10-30.00(s)

1.00

b031

Software lock mode selection

00(impossible to change the data except this item when SFT terminal is
ON)/01(impossible to change the data except setting frequency item when SFT
terminal is ON)/02(impossible to change the data except this item)/
03(impossible to change the data except setting frequency item)/
10(possible to change data on operating)

01

adj

us

tabl

e fu

ncti

o

n

Ex

terna

l freq

uenc

y

adj

us

tmen

t

Accel.

De

ce

l.

In

s

tantane

ous

powe

r f

a

ilur

e

r

e

s

tar

t

El

ectr

oni

c

t

h

er

m

a

l

Over

load l

im

it

Lock

Advertising