Venting installation – FMI PFS DVF42NH-HA User Manual

Page 12

Advertising
background image

www.fmiproducts.com

125078-01B

12

venting inStALLAtiOn

Continued

5.

Noncombustible Exterior Wall: Position

horizontal vent cap in center of the 8

1

/

2

"

round hole and attach to exterior wall

with four wood screws provided. Before

attaching vent cap to exterior wall, run a

bead of non-hardening mastic (pliable

sealant) around outside edges to make a

seal between it and outside wall.

Note: Four wood screws provided should

be replaced with appropriate fasteners for

stucco, brick, concrete or other types of

sidings (see Figure 10).

Combustible Exterior Wall: For vinyl

siding, stucco or wood exteriors, a siding

standoff may be installed between vent

cap and exterior wall. Siding standoff

prevents excessive heat from damaging

siding materials. Siding material must be

cut to accommodate standoff. Bolt vent

cap to standoff. Apply non-hardening

mastic around outside edge of standoff.

Position standoff/cap assembly in the

center of 11

1

/

2

" square hole and attach to

exterior wall with provided wood screws

(see Figure 11). Siding standoff must sit

flush against exterior fascia material.

6.

Connecting Vent Cap with Horizontal

Vent Pipe: Slide wall firestop over vent

pipe before connecting horizontal run to

vent cap (see Figure 12).

Figure 10 - Installing Horizontal Vent Cap

(Noncombustible Exterior)

Wood

Screw

Vent Cap

Figure 11 - Installing Siding Standoff

(Combustible Exterior Wall)

Cut Siding Away to

Fit Standoff

Wood

Screw

Screws

Standoff

Vent

Cap

Apply Mastic

to All Four Sides

Vent Cap

(Horizontal

Termination)

Interior Wall

Surface

Wall

Firestop

Horizontal

Vent Pipe

Figure 12 - Connecting Vent Cap with

Horizontal Vent Pipe

Screw

Apply

Mastic to All

Four Sides

Carefully move fireplace, with vent as-

sembly attached, toward wall and insert

vent pipe into horizontal termination. Pipe

overlap should be a minimum of 1

1

/

4

" (see

Figure 13, page 13).

Slide wall firestop against interior wall

surface and attach with screws provided.

See Figure 13, page 13, for horizontal

termination details.

Place fireplace into position and shim with

noncombustible material if needed. Nail or

screw side flanges to framing to secure

unit in place. IMPORTANT: Make sure fire-

place is level before securing. If fireplace

is not level it will not work properly.

Advertising