Fireplace installation – FMI PFS DVF42NH-HA User Manual

Page 19

Advertising
background image

www.fmiproducts.com

125078-01B

19

FirePLAce inStALLAtiOn

Continued

3. Make sure control knob of fireplace is in

the OFF position.

4. Check all joints from equipment shutoff

valve to gas valve (see Figure 22 or

Figure 23, page 18). Apply noncorrosive

leak detection fluid to all joints. Bubbles

forming show a leak. Correct all leaks at

once.

5. Light fireplace (see Operation, page 22).

Check all other internal joints for leaks.

6. Turn off fireplace (see To Turn Off Gas to

Appliance, page 23).

REMOVING/REPLACING GLASS

DOOR

CAUTION: Do not operate

this fireplace with a broken glass

door panel or without the glass

door panel securely in place.

For replacement part informa-

tion see Replacement Parts,

page 36.

CAUTION: Wear gloves and

safety glasses while handling

or removing broken glass.

Do not remove if glass is hot.

Keep children and pets away

from glass.

WARNING: If fireplace has

been running, turn off fireplace.

Let cool before removing glass

doors.

Figure 24 - Removing/Replacing Door

Removing Glass Door

If replacement of glass is necessary, the entire

frame assembly must be replaced. Gloves

must be worn when removing/replacing glass

door. If glass is broken tape remaining glass

onto frame before removing.
1. Remove screens if installed.
2. Open bottom access panel.
3. Unlock 2 door latches on bottom of

firebox.

4. Tilt open glass door 45° from the bottom

of firebox and lift up to release door from

firebox top retainer (see Figure 24).

Replacing Glass Door

1. Position door frame in front of firebox

opening with bottom of door tilted away

from firebox (see Figure 24).

2. Hook top flange of door frame over top of

firebox frame.

3. Secure 2 bottom door latches.

Door

Retainer

Glass

Door

Bottom

Access Panel

Door

Latches

Advertising