Fireplace installation – FMI PFS DVF42NH-HA User Manual

Page 18

Advertising
background image

www.fmiproducts.com

125078-01B

18

FirePLAce inStALLAtiOn

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping

and connections, internal and

external to unit, for leaks after

installing or servicing. Correct

all leaks at once.

WARNING: Never use an

open flame to check for a leak.

Apply noncorrosive leak detec-

tion fluid to all joints. Bubbles

forming show a leak. Correct all

leaks at once.

pRESSURE TESTING GAS SUppLY

pIpING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

(3.5 kPa)

1. Disconnect fireplace and its individual

equipment shutoff valve from gas supply

piping system. Pressures in excess of 1/2

psig (3.5 kPa) will damage fireplace gas

regulator.

2. Cap off open end of gas pipe where equip-

ment shutoff valve was connected.

3. Pressurize supply piping system by either

opening propane/LP supply tank valve

for propane/LP gas fireplace or opening

main gas valve located on or near gas

meter for natural gas fireplace or using

compressed air.

4. Check all joints of gas supply piping sys-

tem. Apply noncorrosive leak detection

fluid to all joints. Bubbles forming show a

leak. Correct all leaks at once.

5. Reconnect fireplace and equipment

shutoff valve to gas supply. Check recon-

nected fittings for leaks.

Test Pressures Equal To or Less Than

1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Fig-

ure 21).

2. Pressurize supply piping system by either

opening propane/LP supply tank valve

for propane/LP gas fireplace or opening

main gas valve located on or near gas

meter for natural gas fireplace or using

compressed air.

Figure 21 - Equipment Shutoff Valve

Open

Closed

Equipment

Shutoff Valve

3. Check all joints from propane/LP supply

tank or gas meter to equipment shutoff

valve (see Figure 22 or Figure 23). Apply

noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak.

4. Correct all leaks at once.

Figure 22 - Checking Gas Joints for

Propane/LP Gas Fireplace

Propane/LP

Supply Tank

Gas Valve

Equipment

Shutoff Valve

pRESSURE TESTING FIREpLACE GAS

CONNECTIONS

1. Open equipment shutoff valve (see Fig-

ure 21).

2. Open propane/LP supply tank valve for

propane/LP fireplace or main gas valve

located on or near gas meter for natural

gas fireplace.

Gas Meter

Gas Valve

Equipment

Shutoff Valve

Figure 23 - Checking Gas Joints for

Natural Gas Fireplace

Advertising