Venting installation – FMI PFS DVF42NH-HA User Manual

Page 15

Advertising
background image

www.fmiproducts.com

125078-01B

15

Figure 16 - Installing Firestop

If area above is a living space, install

firestop below framed hole.

If area above is an attic or insulated area,

install firestop above framed hole.

Note: If vent pipe passes through any occupied ar-

eas above first floor, including storage spaces and

closets, you must enclose pipe. You may frame

and sheetrock enclosure with standard construc-

tion material. Make sure and meet the minimum

allowable clearances to combustibles. Do not fill

any required air spaces with insulation.
Vertical Termination Configurations

Figure 17 shows the configurations for vertical

termination.

venting inStALLAtiOn

Continued

Figure 17 - Vertical Venting Configuration

HIGH ALTITUDE INSTALLATION

Your FMI PRODUCTS, LLC direct vent

fireplace has been tested and approved for

elevations from 0-2000 feet.
Fireplaces for high altitude (-HA Models) are

for installations above 4,000 feet only. These

fireplaces are equipped with parts specific for

higher altitudes.
When installing a non-high altitude fireplace at

an elevation above 2000 feet, you may need

to decrease the input rating by changing the

existing burner orifice to a smaller size. Reduce

input 4% for each 1000 feet above sea level.

Check with your local gas company for proper

orifice size identification.
When installing this fireplace at an elevation

above 4500 feet, check with local authorities.

PARTS LIST FOR VENTING KITS

AND COMpONENTS

FMI (5/8") Pipe & Vent Kits

Number Description

P58-6

6" Section Double Wall Pipe,

Galvanized

P58-12

12" Section Double Wall Pipe,

Galvanized

P58-24

24" Section Double Wall Pipe,

Galvanized

P58-36

36" Section Double Wall Pipe,

Galvanized

P58-48

48" Section Double Wall Pipe,

Galvanized

PA58-712 Adjustable 7"-12" Section Double

Wall Pipe, Galvanized

E58-45

45° Elbow, Galvanized

E58-90

90° Elbow, Galvanized

HTS-58 Horizontal Square Termination,

Galvanized

HHT-58 High Wind Round Termination,

Galvanized

VT-58

Vertical Round Termination,

Galvanized

SC-58

Storm Collar, Galvanized

WF-58

Wall Firestop, Galvanized

RF-58-6 Roof Flashing - 0 to 6/12 Pitch,

Galvanized

RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch,

Galvanized

VR-58

Vertical Restrictor, Galvanized

S-58

Vinyl Siding Standoff, Galvanized

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing - For use with

HTS-58

RF-58

Flat Roof Flashing

Vertical

Venting

V = 40' max.