Fireplace installation – FMI PFS DVF42NH-HA User Manual

Page 17

Advertising
background image

www.fmiproducts.com

125078-01B

17

Check your building codes for any special

requirements for locating equipment shutoff

valve to fireplaces.
Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from

going into pipe. Excess sealant in pipe could

result in clogged fireplace valves.

FirePLAce inStALLAtiOn

Continued

Figure 19 - Gas Connection

Equipment Shutoff Valve

with 1/8" NPT Tap*

3" Minimum

Approved

Flexible

Gas Line

Cap Pipe

Tee

Joint

Nipple

Sediment Trap/

Drip Leg

Natural - From

Gas Meter (5.5"

W.C. to 10.5" W.C.

Pressure)

Propane/LP From

External Regulator

(11" W.C. to 14"

W.C. Pressure)

* The equipment shutoff valve may be sup-

plied with the appliance or you can purchase

it from your retailer.

Figure 20 - Connecting Incoming Gas Line to Flex Gas Line

Red Surface Indicates For

Propane/LP Use Only

Pilot Adjustment

Inlet Pressure Tap

Outlet Pressure Tap

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install a sediment

trap/drip leg in supply line as shown in Figure

19. Locate sediment trap/drip leg where it is

within reach for cleaning. Install in piping sys-

tem between fuel supply and fireplace. Locate

sediment trap/drip leg where trapped matter

is not likely to freeze. A sediment trap traps

moisture and contaminants. This keeps them

from going into fireplace gas controls. If sedi-

ment trap/drip leg is not installed or is installed

wrong, fireplace may not run properly.

CONNECTING FIREpLACE TO GAS

SUppLY

Installation Items Needed

• 5/16" hex socket wrench or nut-driver
• sealant (resistant to propane/LP gas, not

provided)

1. Route flexible gas line (provided by in-

staller) from equipment shutoff valve to

fireplace. Route flexible gas supply line

through one of the access holes on side

of fireplace.

2. Attach flexible gas line from gas supply to

control valve (see Figure 20).

3. Check all gas connections for leaks. See

Checking Gas Connections, page 18.

IN

PILOT

IN

OUT

VENT

TH

TP

TH TP

Gas Shutoff

Valve

Flexible

Gas Line

Do NOT

Kink

1/2" NPT

Incoming

Gas Line

Note:

1) Wire connections not

shown for clarity

2) * 1/8" NPT Plugged

Tapping