OBSERVED PROBLEM

Pilot will not stay lit

No gas to burner, although

safety shutoff switch and valve

are set to the ON position

Frequent pilot outage

Fireplace produces a clicking/

ticking noise just after burner

is lit or shut off

Slight smoke or odor during

initial operation

REMEDY

1. Check wiring connection.

Refer to wiring diagram

(see Wiring Diagram, page

29) and/or check ground

wire to ignition module

2. Clean and adjust pilot burn-

er and check gas supply

and inlet pressure to unit

Note: Have a qualified

technician replace pilot

assembly if broken or cor-

roded

1. Check electrical connec-

tions

1. Clean and adjust pilot flame

for maximum flame im-

pingement on thermopile

2. Have vent system inspect-

ed, including termination

cap. Remove any restriction

or obstruction

1. This is normal with most

fireplaces. If noise is ex-

cessive, contact qualified

service person

1. Problem will stop after a few

hours of operation

trOUbLeShOOting

Continued

pOSSIBLE CAUSE

1. Loose wiring on ignitor wire

to ignition module and/

or poor ground to ignition

module

2. Pilot flame too low to

sense

1. Safety shutoff switch wires

defective or too long

1. Pilot flame may be too low,

causing safety pilot to “drop

out”

2. Improper venting or exces-

sive blockage

1. Metal expanding while

heating or contracting while

cooling

1. Residues from manufac-

turing processes and logs

curing