trOUbLeShOOting

Continued

WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Fol-

low the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

pOSSIBLE CAUSE

1. Gas leak.

See Warning

statement at top of page

2. Control valve defective

1. Foreign matter between

control valve and burner

2. Gas leak.

See Warning

statement at top of page

1. Debris around burner air

mixer

2. Improper vent configuration

1. Air holes at burner inlet

blocked

2. Burner flame holes blocked

3. Improper venting or exces-

sive blockage

4. Excessive amounts of em-

bers and pan material

OBSERVED PROBLEM

Gas odor even when gas

control valve is off

Gas odor during combustion

Glass soots

Dark residue on logs or inside

of fireplace

REMEDY

1. Locate and correct all leaks

(see Checking Gas Con-

nections, page 18)

2. Replace control valve

1. Take apart gas tubing and

remove foreign matter

2. Locate and correct all leaks

(see Checking Gas Con-

nections, page 18)

1. Inspect opening at base of

burner to see that it is NOT

packed with any type of

material

2. Check vent configuration

specification (see Venting

Installation, page 10)

1. Clean out air holes at burn-

er inlets. Periodically repeat

as needed

2. Remove blockage

3. Have vent system inspect-

ed, including termination

cap. Remove any restric-

tions or obstruction

4. Clear excess embers until

a minimum gap of 1/2"

remains under grate