Venting installation – FMI PFS DVF42NH-HA User Manual

Page 13

Advertising
background image

www.fmiproducts.com

125078-01B

13

venting inStALLAtiOn

Continued

Figure 13 - Typical Horizontal

Termination Cap Mounting with

Additional Siding Standoff Installed

Siding

Standoff

Screws

High Wind

Termination

Apply

Mastic to

Outside

Edge of

Standoff

Exterior Wall with Vinyl Siding

11

1

/

2

" x 11

1

/

2

"

Framed Opening

Maintain 1"

Minimum Air

Space Around

Outer Pipe When

Penetrating a Wall

Minimum

Pipe

Overlap

1

1

/

4

Wall

Firestop

Direct

Vent

Pipe

Horizontal Termination Configurations

Figure 14 shows a configuration for venting

with horizontal termination with a chart of

critical minimum and maximum dimensions

which MUST be met.

NOTICE: Do not seal termination

cap to vent pipe. Cap must be

removable for vent inspection

and maintenance.

WARNING: Never run vent

downward as this may cause

excessive temperatures which

could cause a fire. Operation of

improperly installed and main-

tained venting system could

result in serious injury, property

damage or loss of life.

GROUND FLOOR INSTALLATION

Recommended Applications:

• Through the wall using round or square

termination

• NOT FOR CORNER INSTALLATION

Figure 14 - Horizontal Termination Using

One 90° Elbow

Vertical Termination Installation

Note:

Vertical restrictor must be installed in

all vertical installations.
1. Determine route your vertical venting will

take. If ceiling joists, roof rafters or other

framing will obstruct venting system, con-

sider an offset (see Figure 15, page 14)

to avoid cutting load bearing members.

Note: Pay special attention to these instal-

lation instructions for required clearances

(air space) to combustibles when passing

through ceilings, walls, roofs, enclosures,

attic rafters, etc. Do not pack air spaces

with insulation. Also note maximum

vertical rise of venting system and any

maximum horizontal offset limitations.

Wall

Firestop

H

90° Elbow

V + 90· Elbow

Horizontal High

Wind Square

Termination

64" Min. (42")

61" Min. (36")

1' Pipe Min On

Horizontal Run

(V) Vertical

Minimum

Required

Vertical Pipe

(H) Horizontal

Maximum

21"

1 ft.

3 ft.

33"

2 ft.

7 ft.

45"

3 ft.

11 ft.

57"

4 ft.

20 ft.

V + H = 40 feet maximum

H = 20 feet maximum

1 ft. Min

Before

Elbow