Fluke 434 User Manual

Page 105

Advertising
background image

Specifications

Electrical Measurements

21

21-3

RMS Voltage

Selected Nominal

Voltage (Vnom)

Measurement Range

(CF ≤ 1.4 at full scale)

Resolution Accuracy

60 ... 125 Vrms

1.0 ... 250.0 Vrms

0.1 Vrms

± 0.5 % of Vnom

125 ... 250 Vrms

1.0 ... 500.0 Vrms

0.1 Vrms

± 0.5 % of Vnom

250 ... 500 Vrms

1.0 ... 999.9 Vrms

0.1 Vrms

± 0.5 % of Vnom


Peak Voltage

Selected Nominal

Voltage (Vnom)

Measurement Range

(CF ≤ 1.4 at full scale)

Resolution Accuracy

60 ... 125 Vrms

0 ... 350 V

1 V

± 5 % of Vnom

125 ... 250 Vrms

0 ... 700 V

1 V

± 5 % of Vnom

250 ... 500 Vrms

0 ... 1400 V

1 V

± 5 % of Vnom


Voltage Crest Factor

Condition Measurement

Range Resolution

Accuracy

Umeas

≈ Vnom

1.0 ... 2.8

0.1

± 5 %


Harmonic and Interharmonic Voltages

Settings Range

Additional

Information

Harmonic selection (n):

DC, 1 ... 50

Grouping: Harmonic Groups
according to IEC61000-4-7

Interharmonic selection:

OFF, 1 ... 49

Grouping: Harmonic and
Interharmonic Subgroups
according to IEC61000-4-7

Amplitude Reference

total RMS / fund. RMS

Used for Relative Amplitude

THD

% total / % fundamental

based on H1 ... H40

Advertising
This manual is related to the following products:

433