Fluke 434 User Manual

Page 68

Advertising
background image

Fluke 433/434

Users Manual

16-2

1

2

3

4

5

A /

L

1

B /

L2

C /

L3

A /

L

1

B /

L2

C /

L3

A /

L

1

B /

L2

C /

L3

DI

P

S

IN

TERRUPTION

S

R

A

PI

D VO

LT

AG

E CH

ANG

E

S

SW

EE

LS

U

N

BA

LA

NCE

FREQ

UENCY

PER PHASE

ALL

PHASES

Figure 16-1. Power Quality Monitor Main Screen

The length of a bar increases if the related parameter is further away from its nominal

value. The bar turns from green to red if an allowed tolerance requirement is violated.
Use the left/right arrow keys to position the cursor on a particular bar and measuring data

belonging to that bar is displayed in the screen header.
Power Quality Monitoring is usually done during a long observation period. The function

is entered via the MONITOR key and a start menu to define immediate or timed start of

the measurement. Minimum duration of the measurement is 2 hours. An usual measuring

period is 1 week.
The Power Quality parameters RMS voltages, Harmonics, and Flicker have a bar for each

phase. From left to right these three bars are related to the phases A (L1), B (L2), and C

(L3).

The parameters Dips/Interruptions/Rapid Voltage Changes/Swells and

Balance/Frequency have a single bar for each parameter representing performance across

three phases.
Most of the Bar Graphs have a wide base indicating adjustable time related limits (for

instance 95 % of time within limit) and a narrow top indicating a fixed 100 % limit. If

one of both limits is violated, the related bar changes from green to red. Dotted horizontal

lines on the display indicate the 100% limit and the adjustable limit.
The meaning of the bar graphs with a wide base and a narrow top is explained below. By

way of example this is done for the RMS voltage. This voltage for instance has a nominal

value of 120 V with a tolerance of + and – 15% (tolerance range between 102 … 138 V).

The momentary RMS voltage is constantly monitored by the Analyzer. It calculates an

Advertising