Table, Trend – Fluke 434 User Manual

Page 45

Advertising
background image

Harmonics

Table

10

10-3

Table

To access the Harmonics Table screen:

f

F3


The table display shows 8 measurements per phase. Using the SETUP key and function

key F3 - FUNCTION PREF you can choose the table contents. For detailed information

see Chapter 18, FUNCTION PREFerences.
Available function keys:

F3

Return to Bar Graph screen.

F4

Access the Trend screen. For description see below.

F5

Switch between HOLD and RUN of screen update.
Switching from HOLD to RUN invokes a menu to select
immediate (NOW) or TIMED start time which allows you
to define start and duration of the measurement.

Trend

To access the Harmonics Trend screen:

g

F4


Trend shows how harmonics vary over time: Cursor and Zoom can be used to investigate

details. All values in the table are recorded, but the Trends from each row in the table are

displayed one at a time. Press function key F1 to assign the arrow keys to row selection.
Using the SETUP key and function key F3 - FUNCTION PREF you can choose

harmonics display as a percentage of fundamental voltage (%f) or of the total of

harmonic voltages (%r, total Vrms). Also the table contents can be selected in this menu.

For detailed information see Chapter 18, FUNCTION PREFerences.
Available function keys:

F1

Assign up/down arrow keys to select a row from the table
for Trend display.

F2

Cursor on/off.