Farallon Communications NetopiaTM User Manual

Page 51

Advertising
background image

Troubleshooting

51

T

HE

“COM P

ORT

IS

EITHER

IN

USE

OR

UNAVAILABLE

OR

“P

ORT

NOT

OPEN

ERROR

MESSAGE

APPEARS

.

An incorrect Interrupt Request Line (IRQ) may be assigned to the
COM por t. Most computers have pre-assigned an IRQ# to each
COM#. These include the following:

COM1 and IRQ4

COM2 and IRQ3

COM3 and IRQ4

COM4 and IRQ3

If PC Card Ser vices has assigned different combinations for the
COM por t and IRQ, you must reassign these numbers accordingly.
To reassign your COM por t and IRQ, use PC Card Ser vices or the
appropriate settings utility for your operating system.

T

HERE

IS

A

POSSIBLE

CONFLICT

BETWEEN

THE

PC C

ARD

AND

YOUR

SERIAL

MOUSE

.

Per form the following test:

1.

Remove your Netopia ISDN PC Card from your PC Card slot
and re-inser t it.

2.

Activate a terminal emulation program.

3.

Enter $Xmit. Press Enter until the PC Card responds with the
following display:

NetopiaCard Xmit test: Enter to start, Enter to stop

4.

Press Enter again. The card will continuously transmit this
line:

ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789abcdefghijkl

To check if there is a conflict with the mouse, move the mouse
around during the Xmit test. If this causes the transmission to
stop or display meaningless characters on your screen, there is
probably a conflict, and the mouse driver must be removed or
reconfigured to another IRQ.

Advertising