2) External Signal Operation

Ensure that the connection is as shown in the following diagram in case of operating the drive
by means of external frequency setting potentiometer or contact signal.

Note 1) Set function F02 to 1.

Note 2) In case of using an external frequency setting potentiometer, disconnect the potenti-
ometer connector (CN2) from the keypad panel. Use of an external potentiometer together
with the potentiometer on the keypad panel may result in damage to the drive.

* PE terminal blocks for the drive and motor should be provided in the cabinet in which the
drive is installed in.

Power supply

AC220-240V

50/60Hz

1 Phase

Potentiometer for
frequency setting

FAB

Thermal Relay

Forward-direction operation command

U

V

W

FM

THR (X1)

CM

RST

BX (X2)

REV

FWD

M

L1

L2

13

12

11

x

CN2

8 8 8

FVR-C9S

Reverse-direction operation command

Motor coast-to-stop command

External alarm input

Analog monitor

10V 1mA

Alarm reset

PE

30A

30B

30C

C1

Fault

E(G)