FVR-C9S-7UX

F 2 9 Multistep Speed Setting 1 (Speed 1)
F 3 0 Multistep Speed Setting 2 (Speed 2)
F 3 1 Multistep Speed Setting 3 (Speed 3)

Multistep speeds can be set within a range of 0 to 120 Hz only by changing the contact signal from outside.
(X1-CM X2-CM). Setting of speed of optional step is possible within a range of 0 to 120 Hz during drive
operation
(Note1) X1 or X2 terminal is selected via THR/BX terminal function change (F27, F28)
(Note 2) In selecting THR/BX terminal function (F27, F28) individual setting is possible.

Speed 0

Frequency setting is made by either the analog signal or the keypad panel.

Terminal / Function Code

F27 : 1

F27: 0

F27: 1

F27: 0

F28: 0

F28: 1

F28: 1

F28: 0

THR

X1

External Alarm input

X1

External alarm imput

BX

Motor coast-to-stop
command imput

X2

X2

Motor coast-to-stop
command imput

C92-09

Speed 1

Speed 2

Speed 3

Speed 0

Time

THR-CM (X1)

BX-CM (X2)

FWD-CM

ON

ON

ON

ON