F 1 4 Starting Frequency

The starting frequency can be set in increments of 1 Hz within a range of 1 to 6 Hz. Note that stopping will
also occur at the frequency set by this function.

1 1 Hz

6 6 Hz

Set to 2 Hz when using a high speed motor.

F 1 5 Motor Running Sound

The sound of the motor operation can be changed by changing the carrier frequency.

0 Select from among 5 levels in accordance with the usage conditions.
5

Data code

0 Low carrier frequency
5 High carrier frequency (low noise)

F 1 6 Fault Memory

The current and previous 3 fault events are stored in memory.
The data for each can be displayed by using the DOWN key.
The procedure for displaying the data is as follows:

The information for any new trip will be stored in the area for the "information for the latest trip" shown
above, each trip history will be removed downward and the "information for the third preceding trip"
will be erased.

Output
frequency

Starting
frequency

1

No.

Procedure

Display

(ex)

Remarks

1

Display

F

1

6

F

1

6

2

Press FUNC/DATA Key

Press UP Key

The information for the latest
trip will be displayed

F

0

1

3

Press DOWN Key

Press UP Key

The information for the first
preceding trip will be displayed

O

H

2

4

Press DOWN Key

Press UP Key

The information for the second
preceding trip will be displayed

O

C

1

5

Press DOWN Key

Press UP Key

The information for the third
preceding trip will be displayed.
(in this example, there is no
history of a third preceding trip).

-

-

-

6 Press DOWN Key

E

n

d