FVR-C9S-7UX

Type (FVR _ _ _ C9S-7UX)

F12

F25

F50

001

002

Applicable motor output

1

[Hp]

1/8

1/4

1/2

1

2

Frequency setting

Key operation:

Setting with UP/DOWN keys

Potentiometer:

Terminal for 1-5K ohm VR is provided

Analog signal:

0-5 VDC 0-10 VDC (resistance = 12k ohm)
4-20 mA (resistance = 250 ohm)

Display

Run mode Output frequency is displayed. (3 digit LED)

Fault mode Cause of fault is displayed.

Other LED comes on with charging voltage applied.

Acceleration/Deceleration time

0-60s (Variable setting) Acceleration time and deceleration

Control

time can be set independently.

Voltage frequency characteristics

Setting of maximum frequency/base frequency is variable.

Restart after momentary power failure "Automatic restart" setting makes it possible to keep motor

running and restart drive in case of a momentary power failure.

High Limiter & Low Limiter

Upper limit and lower limit of frequency can be set.

Bias setting

Bias setting is possible with respect to analog frequency setting.

Jump frequency

Three jump points and one jump width can be set.

Torque boost

Setting variable in 32 steps.

Starting torque

[%]

150% for 60 seconds.

Braking torque

5

[%]

150% 1 min.

100% 1 min.

50% 1 min.

Braking

DC brake

Brake starting frequency: 3 Hz (fixed)
Setting of braking current / braking time is variable.

Overload

Detects overload current and stops drive.

Momentary overcurrent

Protects drive In case of ground fault (detects at start) and
short circuit of output circuit.

Overvoltage

Detects overvoltage of DC bus and stops drive.

Protection

Overheating of cooling element

Detects abnormal temp. rise of cooling element and stops drive.

Motor protection

Protects standard 4-pole motor and forced-air cooled motor by
means of electronic thermal overload relay.

Alarm protection

Outputs contact signal in case of a trip for protection
(1c contact capacity: AC250V 0.3A cos = 0.3)

Installation location

Indoor at an altitude of 3283 feet (1000m) or less and free of
dust, corrosive gas and oil mist.

Ambient temperature

-10 to 50

°

C

Ambient humidity

20 -90% RH (There shall be no dew condensation)

Environment Vibration

19 feet/s

2

(5.9m/s

2

) or less

Vibration frequency: 5 - 55 Hz

Storage temperature

-25 to 65

°

C

Atmospheric pressure

Operation/storage: min 900 mb (equivalent to 3283 feet (1000m)
Transport: min 660 mb (equivalent to 10720 feet (3265m)

Enclosure

IP20

Cooling method

Self-cooling (up to 1 Hp), forced-air cooling (2 Hp)

5) This indicates average braking torque of a single motor. (Value varies according to motor efficiency.