User instructions – Stovax Aspen User Manual

Page 11

Advertising
background image

11

USER INSTRUCTIONS

7.9.6 Place the two thin logs (No. 12), one at each side sitting on

the tray and resting against the previously positioned logs.
Place one log (No. 9) at the LH rear resting on the base log,
and one log (No. 8) at the RH rear. See diagram 32.

8.1

The appliance is fitted with an oxygen sensitive pilot system
that will act to cut off the gas supply to the fire should the
oxygen in the room fall below its normal level. If the fire is
turned off by this device, it usually indicates that there is a
problem with the flue system, and this should be inspected
by a qualified engineer.
Do not attempt to use the fire until an engineer says it is
safe to do so.

This device is not a substitute for an independently
mounted carbon monoxide detector.

9.1

This is a safety feature incorporated in all GAZCO fires
which automatically switches off the gas supply if the pilot
goes out and fails to heat the thermocouple.

10.1 The surface coating on the fuel effect used in your GAZCO

fire will "burn off" during the first few hours of use
producing a harmless and temporary odour. This will
disappear after a short period of use. If the odour persists,
ask your installer for advice.

11.1 The fire must be serviced every 12 months by a qualified

Gas Engineer. In all correspondence always quote the
appliance type and the serial number which may be found
on the databadge, located on a chain underneath the
control valve.

11. SERVICING

10. RUNNING IN

AR1286

32

8. OXYGEN DEPLETION SENSOR

9. FLAME FAILURE DEVICE

Advertising
This manual is related to the following products: