Installation instructions, Site requirements, Appliance location – Stovax Aspen User Manual

Page 14: Control upgrade 3

Advertising
background image

14

4.1

This appliance must stand on a non-combustible hearth that
is at least 12mm thick.

4.2

It must be fitted into a non-combustible opening.

4.3

These appliances must be hearth mounted into a fireplace
opening conforming to National Standards.

4.4

The appliance must be firmly fixed to the hearth.

4.5

Ensure that no naked flame or incandescent part of the fire
bed projects beyond the vertical plane of the fireplace
opening.

4.6

The appliance must not be installed in any room that
contains a bath or shower.

4.7

Ensure clearances to combustible materials. See diagram 2.

4. APPLIANCE LOCATION

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

4.8

The following table indicates the minimum opening sizes for
each model. In each case, a gap of 20mm has been allowed
to both Left and Right of the basket. See diagram 3.

MODEL WIDTH

DEPTH

SMALL ASPEN

640mm

400mm

SMALL CHAMONIX

MEDIUM CHAMONIX

690mm

350mm

LARGE ASPEN

790mm

500mm

LARGE CHAMONIX

TAHOE

670mm

300mm

5.1

This appliance is supplied with a control valve that can be
easily upgraded to battery powered remote control. This
upgrade can be fitted by anyone capable of simple DIY jobs
and requires no special training. This upgrade can be
obtained through your local GAZCO stockist.

5.2

STANDARD REMOTE CONTROL This remote control can
control the fire after the pilot has been lit. It can turn the
main burner on and regulate it from low through to high
and back again. It can turn the main burner off leaving the
pilot burning. GAZCO PART NUMBER 8455.