SERVICING INSTRUCTIONS

FAULT FINDING CHARTS

PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE

Ensure there is no debris around the pilot assembly,

(e.g. coal, soot etc.) Check for fluff in the pilot aeration hole.

See diagram 13 arrow A in replacing parts section.

If the appliance goes out in use continually, this may mean that the oxygen

depletion sensor has been activated. The appliance should not be used until the

cause has been found and rectified.

Problem is with the

pipework or

fittings which lead

to the fire. Correct

and retry.

Is thermocouple

connection good

in back of valve?

Replace ODS unit.

Will pilot

stay alight?

Change mag

unit.

Is the pilot flame of the

correct length? See

diagram 13 in replacing

parts section.

Change the

ODS unit.

Will pilot

stay alight?

With the pilot

running is the gas

pressure as stated on

the databadge?

With the fire running

on full is the gas at

the pressure stated

on the databadge?

Run for 3 mins,

turn off, time interval

until mag unit shuts

with a click. Is this

greater than 7

seconds?

Run for 3 mins, turn

off, time interval until

mag unit shuts with a

click. Is this greater

than 7 seconds?

Tighten the

connection and retry.

No

No

No

No

No

No

Yes

SYSTEM OK

Yes

Yes

Yes

Yes

No

Yes

Yes

No

Light the pilot and keep the control knob pushed in

at least 10 seconds before letting go.

FLAME FAILURE FUNCTIONAL CHECK 3

Yes