Installation instructions, Site requirements, Flue and chimney requirements – Stovax Aspen User Manual

Page 13: Ventilation 2. installation of the gas supply

Advertising
background image

13

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

1.1

The chimney or flue system must comply with the rules in
force.

1.2

Fireplace opening up to 450mm (18") wide by 600mm (24")
high will usually work with a 175mm (7") diameter flue.
Larger openings will require bigger flues. See diagram 1 as
a guide.

1. FLUE AND CHIMNEY REQUIREMENTS

1.3

The chimney or flue must be free from any obstruction.
Any damper plates should be removed or secured in the
fully open position, and no restrictor plates should be fitted.

1.4

The chimney should be swept prior to the installation of the
appliance - unless it can be seen to be clean and
unobstructed throughout its entire length.

1.5

Ensure that there is a smooth tapered transition from the
fireplace opening into the chimney or flue.

1.6

The flue pull should be checked prior to installation of the
appliance. Apply a smoke pellet to the flue or chimney
opening and ensure that the smoke is drawn into the
opening. If there is not a definite flow, pre-heat the
chimney for a few minutes and re-test the flow.
IF THERE IS STILL NO DEFINITE FLOW, THE CHIMNEY
MAY REQUIRE ATTENTION - SEEK EXPERT ADVICE.

2.1

Before installation, ensure that the local distribution
conditions (identification of the type of gas and pressure)
and the adjustment of the appliance are compatible.

2.2

Ensure that the gas supply is capable of delivering the
required amount of gas, and is in accordance with the rules
in force.

2.3

Soft copper tubing and soft soldered joints can be used, but
must not be closer than 50mm (2") to the base of the tray.

2.4

A means of isolating the gas supply to the appliance must
be provided independent of any appliance control.

2.5

All supply gas pipes must be purged of any debris that may
have entered prior to connection to the appliance.

It is important to ensure that any national ventilation
requirements are taken into account during the
installation of this appliance.

3.1

This appliance requires an air vent of at least 100cm

2

effective area.

3.2

It is essential to check for flue clearance, see installation
section 6, Commissioning. If spillage is detected, it may be
necessary to provide additional ventilation.

3.3

The ventilation is in addition to any openable window, and
although it must communicate with the outside air,
wherever possible, it can communicate with an adjacent
room provided that the space has a similar vent to the
outside.

3. VENTILATION

2. INSTALLATION OF THE GAS SUPPLY

AR0595

AR0596

A

B

D

C

A

B

C

D

1

mm

mm

cm

2

C

A

B

A x B

3.0m

4.5m

6.0m

9.0m

15.0m

350

550

1925cm2

175

175

175

175

175

400

550

2200cm2

175

175

175

175

175

460

460

2116cm2

175

175

175

175

175

460

550

2530cm2

200

175

175

175

175

460

610

2806cm2

200

200

175

175

175

610

460

2806cm2

200

200

175

175

175

610

610

3721cm2

250

225

200

200

175

610

760

4636cm2

300

250

250

225

200

760

460

3496cm2

225

225

200

200

175

760

610

4636cm2

250

250

250

225

200

760

760

5776cm2

300

300

250

250

225

760

910

6916cm2

350

300

300

250

250

910

460

4186cm2

250

225

225

200

200

910

610

5551cm2

300

300

250

250

225

910

760

6916cm2

350

300

300

250

250

910

910

8281cm2

350

350

300

300

250

910

1070

9737cm2

-

350

350

300

300

1070 460

4922cm2

300

250

250

225

200

1070

610

6527cm2

300

300

300

250

250

1070

760

8132cm2

350

350

300

300

250

1070

910

9737cm2

350

350

300

300

1070

1070

11449cm2

350

350

300

1070

1220

13054cm2

350

350

1220

460

5612cm2

300

300

250

250

225

1220

610

7442cm2

350

300

300

300

250

1220

760

9272cm2

350

350

300

300

1220

910

11102cm2

350

350

300

1220

1070

13054cm2

350

350

1220

1220

14884cm2

350

350

1520

460

6992cm2

300

300

300

250

250

1520

610

9272cm2

350

350

300

300

1520

760

11552cm2

350

350

300

1520

910

13831cm2

350

350

1520

1070

16264cm2

350

1520

1220

18544cm2