Multi-Tech Systems MULTIVOIP MVP210/410/810 User Manual

Page 100

Advertising
background image

Chapter 5: Phonebook Configuration

Multi-Tech

Systems,

Inc.

100

IP

Network

xx xyy yz zz z
J.Q. Publ ic

x xxy yy zz zz
J.Q. Pu bl ic

Central Office

without

standard telephony

Caller ID service

Terminating

VoIP

Generating

VoIP

SPP Protocol

Call is received

here.

Call originates here

at 5:47pm, Sept 27.

phone of:

Henry Brampton

763-555-4077

Display shows:

Clock:

15:26, 5-31

FXS

FXO

CID Flow

Inbound Phone Book

423

Remove Prefix Add Prefix Forward/Addr

{Channel 2}

748

Phone Book Configuration

Gatekeeper RAS Parameters

Q.931 Parameters

Gateway Name: Anoka-Whse-VP3

Add/Edit Inbound Phone Book

Use as default entry

Remove Prefix:

Add Prefix:

Channel Number:

Description:

Channel 2

Shipping Dept

CID Number: 423
CID Name: Shipping Dept

Time Stamp: Date: 0927

Time: 1747

... if “Description” field in Add/Edit

Inbound Phone Book is used

CID Number: 423
CID Name: Anoka-Whse-VP3

Time Stamp: Date: 0927

Time: 1747

... if “Description” in Add/Edit

Inbound Phone Book is blank

OR

Ch1

Ch2

Ch4

Ch3

Figure 5-26: Caller ID example 3


Figure 5-27: VOIP Caller ID Case #3 – Call, through telco central office without standard CID, enters SPP VOIP
system.


IP

Network

xxxyyyzzzz
J.Q. Public

Terminating

VoIP

Generating

VoIP

H.323 Protocol

Call is received

here.

Call originates here

at 4:51pm, Oct 3.

phone of:

Nigel Thurston

763-555-9401

Display shows:

CID Number: 423
CID Name: Anoka-Whse-VP3

Time Stamp: Date: 10/03

Time: 4:51pm

Clock:

10/03, 4:51pm

FXS

FXS

CID Flow

Phone Book Configuration

Gatekeeper RAS Parameters

Q.931 Parameters

Gateway Name: Anoka-Whse-VP3

Inbound Phone Book

423

Remove Prefix Add Prefix Forward/Addr

{Channel 2}

748

CID

CID

Ch4

Ch3

Ch2

Ch1

In x.06 release, when SIP protocol is used,

CID Name field will duplicate value in

CID Number field.

*

*

xxxyyyzzzz
J.Q. Public

401

402

403

404

Figure 5-27: Caller ID example 4

Figure 5-28: VOIP Caller ID Case #4 – Remote FXS call on H.323 VOIP system.


Advertising