Clearances, Warning, Clearances to combustibles mantel clearances – Monessen Hearth Direct Vent Gas Fireplace CDVR36 User Manual
Page 11
69D0023
11
12"
Maximum
Depth
12" Min. for CDV33
13” Min. for CDV36
72” Minimum (CDV33)
71" Minimum (CDV36)
Minimum 6"
from both
side walls (CDV33)
Minimum 4”
from both
side walls (CDV36)
CLEARANCES
CLEARANCES TO COMBUSTIBLES
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than
3
/
4
" from the facing. If it does,
it is considered a mantel and must meet the mantel requirements listed in this manual.
Figure 7 - Clearances
WARNING
Follow these instructions carefully to ensure safe installation. Failure to follow
in struc tions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be
installed on a metal, wood or noncombustible material panel ex tend ing full width and
depth of the appliance.