CHECKING GAS PRES SURE

AND

ELECTRICAL INSTALLATION

1. Check gas type. The gas supply must be the same as

stated on the appliance’s rating decal. If the gas supply
is different from the fireplace, STOP! Do not install
the appliance. Contact your dealer immediately.

2. To ease installation, a 30" (mm) flex line with manual

shut-off valve has been provided with this appliance.
Install and attach

1

/

2

" gas line onto shut-off valve.

3. After completing gas line connection, purge air from

gas line and test all gas joints from the gas meter to
the fireplace for leaks. Use a solution of 50/40 water
and soap or a gas sniffer.

4. To adjust flame height, turn HI/LO knob to HI to get

maximum pressure to burner. Turn HI/LO knob to LO
to get minimum pressure.

5. To check gas pressures at valve, turn captured screw

counter clockwise 2 or 3 turns and then place tubing to
pressure gauge over test point. Turn unit to high. See
Figure 37.
After taking pressure reading, be sure and
turn captured screw clockwise firmly to reseal. Do not
over torque. Check test points for gas leaks.

Figure 37 - Gas Pressure Check at Gas Valve

Pressure

Test “IN”

Pressure

Test “OUT”

HI/LO

Knob

Pilot Adjustment

Screw

ELECTRICAL WIRING

Verify proper operation after servicing.

This fireplace will work without any electrical supply. Electricity is only needed to operate blower.
NOTE: If installed in mobile home, fireplace must be bolted securely to floor.

WARNING

Electrical connections should only be performed by a qualified, licensed electrician.
Main power must be off when connecting to main electrical power supply or performing
service. All wiring shall be in compliance with all local, city, and state codes. The
appliance, when installed, must be electrically grounded in accordance with local
codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA
70 (latest edition) and Canadian Electrical Code, CSA C22.1.

CAUTION

Label all wires before disconnecting when servicing controls. Wiring errors can cause
improper and dangerous operation.

WARNING

Do not use open flame to
check for gas leaks.