Vent installation, Warning – Monessen Hearth Direct Vent Gas Fireplace CDVR36 User Manual

Page 14

Advertising
background image

14

69D0023

1"

3"

1"

1"

VENT INSTALLATION

Figure 9 -

Combustible

Clearances for

Vent Pipe -

CDVR36 and CDVR33

A Minimum of 3" Clearance

to the Top Is Required Along

Horizontal Length until Flue

Pipe Penetrates Outside Wall.

WARNING

A Minimum 1"

Clearance to

Combustibles

Permitted All

Around Flue

at Outside

Wall

REAR VENT INSTALLATION

WARNING

This fireplace must be vented to the outside. The venting system must NEVER be
attached to a chimney serving a separate solid fuel burning appliance. Each gas
appliance must use a separate vent system. Do not use common vent systems.

WARNING

Horizontal sections of this vent system
require a minimum of 3" clearances to
combustibles at the top of the flue and 1"
clearance at the sides and bottom until the
flue penetrates the outside wall.
A minimum
1" clearance all around the flue is acceptable
at this point of penetration.

Vertical sections of this vent system require
a minimum of 1" clearance to combustibles
on all sides of the pipe.