background image

69D0023

31

#1

#2

#3

#4

#5

#6

7#

Electronic Valve

GRAY #7

RED #2

RED #2

BLACK #4

GREEN #6

BLUE #1

BLUE

YELLOW

YELLOW

WHITE #3

MAGENTA #5

15’ Wall Switch Wire

BLACK

WHITE

Switch

RS

OFF

ON

Transformer

Secondary

24V

WHITE

WHITE

GREEN

BLACK

BLACK

Primary - 120V

To Junction Box

Pilot Assembly

Spark
Sense

Ignition Module (Synetek)

HI

LO

EV1

EV2

ELECTRICAL INSTALLATION

ELECTRONIC PILOT IGNITION WIRING

REMOTE WALL SWITCH

Position the wall switch. Do not extend beyond the
15 feet of wire.

OPTIONAL DC REMOTE SYSTEMS

See section entitled Hearth Mount in the Millivolt
hand held remote instructions supplied with the
remote.
1. Using a flat head screw driver, bend the “remote”

tabs up from the bottom of the fireplace. See
Figure 40.

2. Follow the instructions on remote control to snap

the remote cover plate to the remote receiver

3. Connect the wire terminal from the remote

receiver. This replaces the 15' wall switch con-
nection to the switch. See Figure 39.

4. Use the screws that came with the remote control

to mount the remote receiver cover to the bent
up “remote” tabs. See Figure 40.

Figure 39 - Remote Wall Switch Wiring Diagram

Remote Control

Figure 40 - Remote Control Location

“Remote” Tabs

WARNING

Do not connect 110-120 VAC to the
Remote Wall Switch. The appliance
will malfunction.