Ldvr series direct vent gas fireplace, Vertical through-the-roof installation – Majestic Appliances 36LDVR User Manual

Page 19

Advertising
background image

19

LDVR Series Direct Vent Gas Fireplace

10007317

Vertical Through-the-Roof Installation

CFM100

Firestop-Vertical

09/20/00

11"

11"

Joist

Joist

Firestop Spacer

Nails (4)

Upper Floor

Attic Insulation

Shield

Ceiling Instal-

lation

CFM100

Fig. 35 Place firestop spacer(s) and secure.

FP1021

Typical vertical

through the roof

application

3/26/00 djt

Max.

(2.4m)

45°

Max.

(2.4m)

45°

40ʼ

(12m)

Typical

Ceiling

Support

Application

Typical Roof

Support Ap-

plication

FP1021

Typical Offset Installation

Fig. 34 Typical vertical roof applications.

1. Locate your fireplace.

2. Plumb to center of the (4”) flue collar from ceiling

above and mark position.

3. Cut opening equal to 9³⁄₈” x 9³⁄₈” (240 x 240mm).

4. Proceed to plumb for additional openings through

the roof. In all cases, the opening must provide a

minimum of 1 inch clearance to the vent pipe, i.e.,

the hole must be at least 9³⁄₈” x 9³⁄₈” (240 x 240mm).

5. Place fireplace into position.

6. Place firestop(s) #7DVFS or Attic Insulation Shield

#7DVAIS into position and secure. (Fig. 35)

7. Install roof support (Fig. 36 & 37) and roof flashing

making sure upper flange is below the shingles. (Fig.

36)

8. Install appropriate pipe sections until the venting is

above the flashing. (Fig. 36)

9. Install storm collar and seal around the pipe.

10. Add additional vent lengths for proper height. (Fig

38)

11. Apply high temperature sealant to 4” and 7” collars

of vertical vent termination and install.

If there is room above ceiling level,

firestop spacer must be installed on both

the bottom and the top side of the ceiling

joists. If an attic is above ceiling level a

7DVAIS (Attic Insulation Shield) must be

installed. (Fig. 35)

The enlarged ends of the vent section

always face downward. (Fig. 36)

TWL101a

Twist Lock Pipe

2/8/99 djt

3 #5 Sheet Metal

Screws per Joint

Storm Collar

TWL101a

Fig. 36 Roof flashing.

Sealant