Maintenance – Majestic Appliances 36LDVR User Manual

Page 31

Advertising
background image

31

LDVR Series Direct Vent Gas Fireplace

10007317

Burner and Burner Compartment
It is important to keep the burner and the burner

compartment clean. At least once per year the logs and

lava rock/ember material should be removed and the

burner compartment vacuumed and wiped out. Remove

and refit the logs as per the instructions in this manual.

Always handle the logs with care as they

are fragile and may also be hot if the

fireplace has been in use.

FK24/FK12 Fan Assembly
The fan unit requires periodic cleaning. At least once

per month in the operating season open the lower

louvre panels and wipe or vacuum the area around the

fan to remove any build up of dust or lint.
Brass Trim
Clean the brass trim pieces using a soft cloth lightly

dampened with lemon oil. Do not use water or

household cleaners on any brass components.

Cleaning the Standing

Pilot Control System

The burner and control system consist of:

burner

gas orifice

pilot assembly

thermopile

millivolt gas valve

Most of these components may require only an

occasional checkup and cleaning and some may

require adjustment. If repair is necessary, it should

be performed by a qualified technician.
1. Turn off pilot light at gas valve.
2. Allow fireplace to cool if it has been operating.
3. Remove window frame assembly. (Refer to Window

Frame Assembly Removal section.)

4. Remove logs.
5. Vacuum burner compartment especially around

orifice primary air openings.

6. Visually inspect pilot. Brush or blow away any dust

or lint accumulation.

7. Reinstall logs.
8. Ignite pilot - Refer to Lighting Instructions.
9. Reinstall window frame assembly.

To obtain proper operation, it is imperative that the pilot

and burnerʼs flame characteristics are steady, not lifting

or floating.
Typically, the top 3/8” to 1/2” of the thermopile should

be engulfed in the pilot flame. (Refer to Page 25, Figure

47)
To adjust pilot burner: (by qualified service technician)
1. Remove pilot adjustment cap
2. Adjust pilot screw to provide properly sized flame.
3. Replace pilot adjustment cap.
The primary air shutter is set at factory and should

only be adjusted, if necessary, by a qualified service

technician.

Maintenance

Advertising
This manual is related to the following products: