LDVR Series Direct Vent Gas Fireplace

10007317

Installation
1. Thread the wiring through the holes on the end

panels of the fireplace. Take care not to cut the wire

or insulation on metal edges. Route the wire to a

conveniently located receptacle box.

2. Attach the wire to the ON/OFF switch and install the

switch into the receptacle box.

3. Connect the other ends of the wire to the gas control

valve. (Fig. 6)

The gas pipeline can be brought in through the rear

of the appliance as well as the bottom. Knockouts are

provided on the bottom behind the valve to allow for the

gas pipe installation and testing of any gas connection.

It is most convenient to bring the gas line in from the

rear right side of the valve as this allows fan installation

or removal without disconnecting the gas line.
The gas line connection can be made with properly

tinned 3/8” copper tubing, 3/8” rigid pipe or an ap-

proved flex connector. Since some municipalities have

additional local codes, it is always best to consult your

local authority and the National Fuel Gas Code, ANSI

Z223.1/NFPA 54 in the USA or the CSA-B149.1 instal-

lation code.

Do not wire the remote ON/OFF wall switch

for the gas fireplace to the 120 volt power

supply.

Alternate Switch Location

The remote switch can be installed on the front/side

of the access door. Simply mount the switch to the

bracket provided and screw the bracket to either side

of the frame, lining up the screws with the pre-punched

holes. (Fig. 7)

The gas control is equipped with a captured screw type

pressure test point, therefore it is not necessary to pro-

vide a 1/8” test point up stream of the control.
When using copper or flex connector use only approved

fittings. Always provide a union when using black iron

pipe so the gas line can be easily disconnected for

burner or fan servicing. See gas specification for pres-

sure details and ratings.
The fireplace valve must not be subjected to any test

pressures exceeding 1/2 psi. Isolate or disconnect this

and any other gas appliance control from the gas line

when pressure testing.

Gas Line Installation

Remote ON/OFF Switch

When purging the gas lines, the front win-

dow frame assembly must be removed.

Always check for gas leaks with a mild

soap and water solution. Do not use an

open flame for leak testing.

FP297A

INSTA VENT FREE

UVHB26 GAS SUPPLY

7/1/98

FP297A

1/2” Gas Supply

1/2” NPT x 1/2” Flare Shut-

off Valve

3/8” Flex Line

(From Valve)

Fig. 5 Typical gas supply installation.

FP1024

alternate

remote switch

location

1/27/00 djt

FP1024

Fig. 7 Alternate switch location.

TP

TH

TP

TH

FP1224

Remote switch

11/02

Remote ON/OFF Switch

or Thermostat

or Remote Control

Gas

Control

Valve

FP1224

Fig. 6 Remote switch wiring diagram.