Majestic Appliances 36LDVR User Manual

Page 6

Advertising
background image

6

LDVR Series Direct Vent Gas Fireplace

10007317

Max.

Min.

Input

Input

Model

Fuel Gas Control BTU/h BTU/h

33LDVRRN Nat

Millivolt

16,000 11,200

33LDVRRP Prop

Millivolt

16,000 12,000

33LDVREN Nat

24V Hi/Lo

16,000 11,200

33LDVREP Prop* 24V Hi/Lo

16,000 12,000

36LDVRRN Nat

Millivolt

19,500 13,650

36LDVRRP Prop

Millivolt

19,500 14,625

36LDVREN Nat

24V Hi/Lo

19,500 13,650

36LDVREP Prop* 24V Hi/Lo

19,500 14,625

39LDVRRN Nat

Millivolt

23,000 16,100

39LDVRRP Prop*

Millivolt

22,500 16,875

39LDVREN Nat

24V Hi/Lo

23,000 16,100

39LDVREP Prop* 24V Hi/Lo

22,500 16,875

43LDVRRN Nat

Millivolt

26,000 18,200

43LDVRRP Prop*

Millivolt

24,000 18,000

43LDVREN Nat

24V Hi/Lo

26,000 18,200

43LDVREP Prop* 24V Hi/Lo

24,000 18,000

Noncombustible materials such as brick or tile may be

extended over the edges of the face of the fireplace.

DO NOT cover any vent or grille panels.

If a Trim Kit is going to be installed on the fireplace, the

brick or tile will have to be installed flush with the edges

of the fireplace.

Final Finishing

Gas Specifications

33LDVR / 36LDVR / 39LDVR / 43LDVR

Certified To

ANSI Z21.88b-2003 / CSA 2.33b-2003

Vented Gas Fireplace Heaters

Framing and Finishing

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Gas Inlet and Manifold Pressures

Natural

LP (Propane)

High Elevations

Input ratings are shown in BTU per hour and are

certified without deration for elevations up to

4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,

installations must be in accordance with the cur-

rent ANSI Z223.1/NFPA 54 and/or local codes hav-

ing jurisdiction.
In Canada, please consult provincial and/or local

authorities having jurisdiction for installations at

elevations above 4,500 feet (1,370m).

Check fireplace to make sure it is levelled

and properly positioned.

To mount the appliance:

1. Choose the location.

2. This unit comes with four (4) flanges pre-mounted

on both sides of the fireplace to allow two different

drywall thicknesses to be used. Flange “A” is for

1/2” drywall while flange “B” is for 5/8” drywall.

3. Bend the desired flanges out 90° on both sides of

the fireplace. Slide the fireplace into the framed

opening until the flanges contact the front surfaces

of the framing. Level the unit and secure it firmly in

place.

FP1544

nail flange

1/05

Fig. 4 Nailing flanges.

Flange

Drywall

Position

Depth

A

1/2” / 13 mm

B

5/8” / 16 mm

Flange Location for

Desired Drywall Depth

FP1539

A

B

33LDVR units: GFRN2I0, GFRL2I0, GFRE2I0
36LDVR units: GFRN2J0, GFRL2J0, GFRE2J0
39LDVR units: GFRN2K0, GFRE2K0
43LDVR units: GFRN2N0, GFRE2N0

*Using conversion kit

Advertising
This manual is related to the following products: