Ldvr series direct vent gas fireplace, Electronic gas control valve eb-1 electrical box – Majestic Appliances 36LDVR User Manual

Page 8

Advertising
background image

8

LDVR Series Direct Vent Gas Fireplace

10007317

The fireplace, when installed, must be

electrically connected and grounded in

accordance with local codes or, in the ab-

sence of local codes, with the current CSA

C22.1 Canadian Electrical Code.

For USA installations follow local codes

and the national electrical code ANSI/

NFPA No. 70.

It is strongly suggested that the wiring of

the EB-1 Electrical Junction Box be carried

out by a licensed electrician.

Ensure that the power to the supply line

has been disconnected before commenc-

ing this procedure.

The EB-1 Electrical junction box has been fitted stand-

ard on this model to allow for the easy connection of an

optional fan kit.

To connect the EB-1 box to the house electrical supply

follow the steps below.

1. Unscrew the retaining screw from the EB-1 base

plate and remove the EB-1 assembly from the

appliance. (Fig. 8)

2. Remove the front cover of the EB-1 box.

3. Remove the plug socket assembly from the EB-1

box.

4. Feed the supply line in through the EB-1 opening in

the side of the appliance and then through the back

of the EB-1 assembly. (Fig. 8)

5. Connect the black wire of the power supply line to

the brass screw (polarized) of the socket assembly.

6. Connect the white wire of the power line to the

chrome screw of the socket assembly.

7. Connect the ground wire of the supply line to the

green screw of the socket assembly.

8. Refit the socket assembly back into the electrical

box and replace the cover plate. Secure the cable

with the clamp on the outside of the EB-1 base

plate and refit the EB-1 assembly to the unit with the

screw removed in step 1.

This appliance may be fitted with a Synetek ignition

module.
Installation of the remote on/off starter switch or

wall thermostat on electronic ignition units.
1. Thread the wiring through the holes on the side

panels of the appliance. Take care not to cut the wire

or insulation on metal edges. Route the wire to a

conveniently located receptacle box.

2. Attach the wire to the ON/OFF switch and install the

switch into the receptacle box.

3. Connect the white wire from the wall switch or wall

thermostat to the white wire terminal from the elec-

tronic module. Connect the black wire from the wall

switch or the red wire from the wall thermostat, to

the red wire terminal from the electronic module.

Electronic Gas Control Valve

EB-1 Electrical Box

FP580

INSTA VENT FREE

EB1 JUNCTION BOX

11/18/97

OUTSIDE

������������

INSIDE

BACK OF UNIT

FP580

Electrical Box

Retaining Screw

Fig. 8 EB-1 receptacle.

Advertising