MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual

Page 22

Advertising
background image

23

66

Stall prevention operation reduction
starting frequency

0 to 400Hz

0.01Hz

60Hz

30

Re

try

67

Number of retries at alarm occurrence

0 to 10, 101 to 110

1

0

34

68

Retry waiting time

0 to 10s

0.1s

1s

34

69

Retry count display erase

0

1

0

34

70

Special regenerative brake duty

*2

0 to 10%

0.1%

0%

31

71

Applied motor

0, 1, 2, 20

1

0

34

72

PWM frequency selection

0 to 15/0 to 6, 25

*1

1

2

35

73

Analog input selection

0 to 7, 10 to 17

1

1

35

74

Input filter time constant

0 to 8

1

1

36

75

Reset selection/disconnected PU
detection/PU stop selection

0 to 3, 14 to 17

1

14

36

76

Alarm code output selection

0, 1, 2

1

0

36

77

Parameter write selection

0, 1, 2

1

0

36

78

Reverse rotation prevention selection

0, 1, 2

1

0

36

79

Operation mode selection

0, 1, 2, 3, 4, 6, 7

1

0

37

Sim

ple

m

a

gne

tic

fl

ux

ve

ct

or

co

nt

ro

l

80

Motor capacity (simple magnetic flux
vector control)

0.4 to 55kW, 9999
/0 to 3600kW, 9999

*1

0.01/0.1kW

*1

9999

37

90

Motor constant (R1)

0 to 50

Ω, 9999

/0 to 400m

Ω, 9999

*1

0.001

Ω/

0.01m

*1

9999

37

Adj

us

tabl

e 5

p

oi

nt

s V/

F

100

V/F1 (first frequency)

0 to 400Hz, 9999

0.01Hz

9999

38

101

V/F1 (first frequency voltage)

0 to 1000V

0.1V

0V

38

102

V/F2 (second frequency)

0 to 400Hz, 9999

0.01Hz

9999

38

103

V/F2 (second frequency voltage)

0 to 1000V

0.1V

0V

38

104

V/F3 (third frequency)

0 to 400Hz, 9999

0.01Hz

9999

38

105

V/F3 (third frequency voltage)

0 to 1000V

0.1V

0V

38

106

V/F4 (fourth frequency)

0 to 400Hz, 9999

0.01Hz

9999

38

107

V/F4 (fourth frequency voltage)

0 to 1000V

0.1V

0V

38

108

V/F5 (fifth frequency)

0 to 400Hz, 9999

0.01Hz

9999

38

109

V/F5 (fifth frequency voltage)

0 to 1000V

0.1V

0V

38

P

U

c

on

nec

to

r

co

m

m

uni

ca

tio

n

117

PU communication station

0 to 31

1

0

38

118

PU communication speed

48, 96, 192, 384

1

192

38

119

PU communication stop bit length.

0, 1, 10, 11

1

1

38

120

PU communication parity check

0, 1, 2

1

2

38

121

Number of PU communication retries

0 to 10, 9999

1

1

38

122

PU communication check time interval

0, 0.1 to 999.8s, 9999

0.1s

9999

38

123

PU communication waiting time setting

0 to 150ms, 9999

1

9999

38

124

PU communication CR/LF presence/
absence selection

0, 1, 2

1

1

38

125

Terminal 2 frequency setting gain
frequency

0 to 400Hz

0.01Hz

60Hz

39

126

Terminal 4 frequency setting gain
frequency

0 to 400Hz

0.01Hz

60Hz

39

PI

D

ope

ra

tion

127

PID control automatic switchover
freqeuncy

0 to 400Hz, 9999

0.01Hz

9999

39

128

PID action selection

10, 11, 20, 21, 50, 51, 60,
61

1

10

39

129

PID proportional band

0.1 to 1000%, 9999

0.1%

100%

39

130

PID integral time

0.1 to 3600s, 9999

0.1s

1s

39

131

PID upper limit

0 to 100%, 9999

0.1%

9999

39

132

PID lower limit

0 to 100%, , 9999

0.1%

9999

39

133

PID action set point

0 to 100%, 9999

0.01%

9999

39

134

PID differential time

0.01 to 10.00s, 9999

0.01s

9999

39

*1

Differ according to capacities. (55K or less/75K or more)

*2

Setting can be made for the 75K or more.

Function

Parameters

Name

Setting Range

Increments

Initial Value

Refer to

page

Advertising