MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual

Page 26

Advertising
background image

27

867

AM output filter

0 to 5s

0.01s

0.01s

32

872

Input phase failure protection selection

0, 1

1

0

42

R

e

ge

ner

at

io

n

av

oi

da

nc

e f

unc

tion

882

Regeneration avoidance operation
selection

0, 1

1

0

45

883

Regeneration avoidance operation level

300 to 800V

0.1V

380V/760V

*1

45

884

Regeneration avoidance at deceleration
detection sensitivity

0 to 5

1

0

45

885

Regeneration avoidance compensation
frequency limit value

0 to 10Hz, 9999

0.01Hz

6Hz

45

886

Regeneration avoidance voltage gain

0 to 200%

0.1%

100%

45

Fr

ee

par

am

e

te

r

888

Free parameter 1

0 to 9999

1

9999

45

889

Free parameter 2

0 to 9999

1

9999

45

En

er

gy

s

avi

n

g

m

oni

to

r

891

Cumulative power monitor digit shifted
times

0 to 4, 9999

1

9999

32

892

Load factor

30 to 150%

0.1%

100%

45

893

Energy saving monitor reference (motor
capacity)

0.1 to 55/0 to 3600kW

*2

0.01/0.1kW

*2

Inverter rated

capacity

45

894

Control selection during commercial
power-supply operation

0, 1, 2, 3

1

0

45

895

Power saving rate reference value

0, 1, 9999

1

9999

45

896

Power unit cost

0 to 500, 9999

0.01

9999

45

897

Power saving monitor average time

0, 1 to 1000h, 9999

1

9999

45

898

Power saving cumulative monitor clear

0, 1, 10, 9999

1

9999

45

899

Operation time rate (estimated value)

0 to 100%, 9999

0.1%

9999

45

Ca

lib

ra

tio

n

p

ara

me

te

rs

C0

(900)

FM terminal calibration

46

C1

(901)

AM terminal calibration

46

C2

(902)

Terminal 2 frequency setting bias
frequency

0 to 400Hz

0.01Hz

0Hz

39

C3

(902)

Terminal 2 frequency setting bias

0 to 300%

0.1%

0%

39

125

(903)

Terminal 2 frequency setting gain
frequency

0 to 400Hz

0.01Hz

60Hz

39

C4

(903)

Terminal 2 frequency setting gain

0 to 300%

0.1%

100%

39

C5

(904)

Terminal 4 frequency setting bias
frequency

0 to 400Hz

0.01Hz

0Hz

39

C6

(904)

Terminal 4 frequency setting bias

0 to 300%

0.1%

20%

39

126

(905)

Terminal 4 frequency setting gain
frequency

0 to 400Hz

0.01Hz

60Hz

39

C7

(905)

Terminal 4 frequency setting gain

0 to 300%

0.1%

100%

39

989

Parameter copy alarm release

10/100

1

10/100

*2

-

PU

990

PU buzzer control

0, 1

1

1

46

991

PU contrast adjustment

0 to 63

1

58

46

Cle

a

r

pa

ra

m

et

er

s

Pr.CL

Parameter clear

0, 1

1

0

46

ALLC

All parameter clear

0, 1

1

0

46

Er.CL

Alarm history clear

0, 1

1

0

46

PCPY

Parameter copy

0, 1, 2, 3

1

0

46

*1

The initial value differs according to the voltage class. (200V class / 400V class)

*2

Differ according to capacities. (55K or less/75K or more)

Function

Parameters

Name

Setting Range

Increments

Initial Value

Refer to

page