MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual

Page 31

Advertising
background image

Features

Standard

Specifications

Outline

Dimension

Drawings

Operation

Panel

Protective

Functions

Options

Instructions

Motor

Compatibility

W

arranty

Inquiry

Peripheral Devices

Why energy

savings?

Te

rminal Connection

Diagram

Te

rminal Specification

Explanation

Parameter

List

Explanations

of

Parameters

32

indicates simple mode parameters and

indicates extended parameters. When setting parameters, refer to the instruction manual (applied) and understand instructions.

Pr.

Pr.

The monitor to be displayed on the main screen of the operation
panel (FR-DU07) / parameter unit (FR-PU04) can be selected.

*1 Selected by the parameter unit(FR-PU04)
*2 The cumulative energization time and actual operation time are

accumulated from 0 to 65535 hours, then cleared, and accumulated again
from 0.
When the operation panel (FR-DU07) is used, up to 65.53 (65530h) is
displayed as 1h=0.001 and then accumulated from 0.

*3 The actual operation time is not added up if the cumulative operation time

before power supply-off is less than 1h.

*4 When using the parameter unit (FR-PU04), “kW” is displayed.
*5 Setting can be made for the 75K or more.
*6 The setting depends on the inverter capacity.(55K or less/75K or more)

⋅ The cumulative power monitor value digit can be shifted to the

right by the number set in Pr. 891.

⋅ By setting “0” in Pr. 170, the cumulative power monitor can be

cleared.

⋅ You can check the numbers of cumulative energization time

monitor exceeded 65535h with Pr. 563 and the numbers of actual
operation time monitor exceeded 65535h with Pr. 564.

⋅ Writing "0" in Pr. 171 clears the actual operation time monitor.

⋅ When Pr. 52 is set to "100", the set frequency monitor is displayed

during a stop and the output frequency monitor is displayed during
operation. (LED of Hz flickers during stop and is lit during
operation.)

⋅ Using Pr. 867 , the output voltage response of the terminal AM can

be adjusted within the range 0 to 5s.

Set the full-scale value to output the output frequency monitor
value to terminal FM and AM.
Set the full-scale value to output the output current monitor value
to terminal FM and AM in Pr. 56.

Change of DU/PU monitor descriptions Cumulative monitor clear

Pr.52 DU/PU main display data selection Pr.54 FM terminal function selection
Pr.158 AM terminal function selection

Pr.170 Cumulative power meter clear

Pr.171 Operation hour meter clear

Pr.268 Monitor decimal digits selection

Pr.563 Energization time carrying-over times

Pr.564 Operating time carrying-over times

Pr.867 AM output filter
Pr.891 Cumulative power monitor digit shifted times

Types of Monitor

Increments

Pr.52 Parameter

Setting Value

Pr.54
(FM)

Pr.158

(AM)

Setting

Full Scale

Value

DU

LED

PU main

monitor

Output frequency

0.01Hz

0/100

1

Pr.55

Output current

0.01A/

0.1A

*6

0/100

2

Pr.56

Output voltage

0.1V

0/100

3

200V
class : 400V
400V
class : 800V

Alarm display

0/100

Frequency setting

0.01Hz

5

*1

5

Pr.55

Running speed

1(r/min)

6

*1

6

Value of Pr. 55
represented in
terms of Pr. 37
value

Converter output
voltage

0.1V

8

*1

8

200V
class : 400V
400V
class : 800V

Regenerative brake
duty

*5

0.1%

9

*1

9

Brake duty set
in Pr. 30 and
Pr. 70

Electronic thermal
relay function load
factor

0.1%

10

*1

10

Electronic
thermal relay
function
operation level

Output current peak
value

0.01A/

0.1A

*6

11

*1

11

Pr.56

Converter output
voltage peak value

0.1V

12

*1

12

200V
class : 400V
400V
class : 800V

Input power

0.01kW/

0.1kW

*6

13

*1

13

Rated inverter
power

× 2

Output power

0.01kW/

0.1kW

*6

14

*1

14

Rated inverter
power

× 2

Input terminal status

55

*1

Output terminal
status

*1

Option input
terminal status

56

×

Option output
terminal status

57

×

Load meter

0.1%

17

17

Pr.56

Reference voltage
output

21

Cumulative
energization time

*2

1h

20

Actual operation
time

*2, 3

1h

23

Motor load factor

0.1%

24

24

200%

Cumulative power

0.01kWh/

0.1kWh

*4, *6

25

Power saving effect

Variable

according

to

parameters

50

50

Inverter
capacity

Cumulative saving
power

51

PID set point

0.1%

52

52

100%

PID measured value

0.1%

53

53

100%

PID deviation value

0.1%

54

Pr.

52, 54, 158, 170, 171, 268, 563, 564, 867, 891

Pr. 268 Setting

Description

9999 (initial value)

No function

0

When 1 or 2 decimal places (0.1 increments or 0.01
increments) are monitored, the decimal places are
dropped and the monitor displays an integer value (1
increments).
The monitor value of 0.99 or less is displayed as 0.

1

When 2 decimal places (0.01 increments) are
monitored, the 0.01 decimal place is dropped and the
monitor displays the first decimal place (0.1
increments).
When the monitor display digit is originally in 1
increments, it is displayed unchanged in 1
increments.

Pr.52

0

100

During

operation/stop

During stop

During

running

Output

frequency

Output frequency

Set frequency

Output frequency

Output

current

Output current

Output

voltage

Output voltage

Alarm

display

Alarm display

Change of the monitor output
from terminal FM and AM

Pr.55 Frequency monitoring reference

Pr.56 Current monitoring reference

Pr.

55, 56

500A

2400

pulse/s

1440

pulse/s

Output frequency
reference
Output current
reference

400Hz

Pr.56

Pulse speed(terminal FM)

Pr.55

10VDC

Output voltage(terminal AM)

400Hz

500A

Pr.56

Pr.55