MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual

Page 24

Advertising
background image

25

In

p

ut

te

rm

inal

f

unc

tio

n ass

ignm

e

nt

178

STF terminal function selection

0 to 8, 10 to 12, 14, 16,
24, 25, 60, 62, 64 to 67,
9999

1

60

41

179

STR terminal function selection

0 to 8, 10 to 12, 14, 16,
24, 25, 61, 62, 64 to 67,
9999

1

61

41

180

RL terminal function selection

0 to 8, 10 to 12, 14, 16,
24, 25, 62, 64 to 67, 9999

1

0

41

181

RM terminal function selection

1

1

41

182

RH terminal function selection

1

2

41

183

RT terminal function selection

1

3

41

184

AU terminal function selection

0 to 8, 10 to 12, 14, 16,
24, 25, 62 to 67, 9999

1

4

41

185

JOG terminal function selection

0 to 8, 10 to 12, 14, 16,
24, 25, 62, 64 to 67, 9999

1

5

41

186

CS terminal function selection

1

6

41

187

MRS terminal function selection

1

24

41

188

STOP terminal function selection

1

25

41

189

RES terminal function selection

1

62

41

Ou

tp

ut

te

rmin

al

fu

n

ct

io

n as

si

gn

m

ent

190

RUN terminal function selection

0 to 5, 7, 8, 10 to 19, 25,
26, 45 to 47, 64, 70, 90 to
96, 98, 99, 100 to 105,
107, 108, 110 to 116, 125,
126, 145 to 147, 164, 170,
190 to 196, 198, 199, 9999

1

0

41

191

SU terminal function selection

1

1

41

192

IPF terminal function selection

1

2

41

193

OL terminal function selection

1

3

41

194

FU terminal function selection

1

4

41

195

ABC1 terminal function selection

0 to 5, 7, 8, 10 to 19, 25,
26, 45 to 47, 64, 70, 90,
91, 94 to 96, 98, 99, 100 to
105, 107, 108, 110 to 116,
125, 126, 145 to 147, 164,
170, 190, 191, 194 to 196,
198, 199, 9999

1

99

41

196

ABC2 terminal function selection

1

9999

41

Mu

lti-s

pe

ed

se

tti

n

g

232 to 239

Multi-speed setting 8 speed to 15 speed

0 to 400Hz, 9999

0.01Hz

9999

28

240

Soft-PWM operation selection

0, 1

1

1

35

241

Analog input display unit switchover

0, 1

1

0

39

242

Terminal 1 added compensation amount
(terminal 2)

0 to 100%

0.1%

100%

35

243

Terminal 1 added compensation amount
(terminal 4)

0 to 100%

0.1%

75%

35

244

Cooling fan operation selection

0, 1

1

1

42

Slip

co

m

pen

sat

ion

245

Rated slip

0 to 50%, 9999

0.01%

9999

42

246

Slip compensation time constant

0.01 to 10s

0.01s

0.5s

42

247

Constant-output region slip
compensation selection

0, 9999

1

9999

42

250

Stop selection

0 to 100s, 1000 to 1100s,
8888, 9999

0.1s

9999

42

251

Output phase failure protection
selection

0, 1

1

1

42

Fr

eq

uen

cy

co

m

pen

sa

tion

fu

n

ctio

n

252

Override bias

0 to 200%

0.1%

50%

35

253

Override gain

0 to 200%

0.1%

150%

35

Li

fe

c

he

ck

255

Life alarm status display

(0 to 15)

1

0

42

256

Inrush current limit circuit life display

(0 to 100%)

1%

100%

42

257

Control circuit capacitor life display

(0 to 100%)

1%

100%

42

258

Main circuit capacitor life display

(0 to 100%)

1%

100%

42

259

Main circuit capacitor life measuring

0, 1

1

0

42

260

PWM frequency automatic switchover

0, 1

1

1

35

Function

Parameters

Name

Setting Range

Increments

Initial Value

Refer to

page