MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual

Page 25

Advertising
background image

Features

Standard

Specifications

Outline

Dimension

Drawings

Operation

Panel

Protective

Functions

Options

Instructions

Motor

Compatibility

W

arranty

Inquiry

Peripheral Devices

Why energy

savings?

Te

rminal Connection

Diagram

Te

rminal Specification

Explanation

Parameter

List

Explanations

of

Parameters

26

Po

w

er

fa

ilur

e

st

o

p

261

Power failure stop selection

0, 1, 2

1

0

43

262

Subtracted frequency at deceleration
start

0 to 20Hz

0.01Hz

3Hz

43

263

Subtraction starting frequency

0 to 120Hz, 9999

0.01Hz

60Hz

43

264

Power-failure deceleration time 1

0 to 3600/ 360s

0.1/0.01s

5s

43

265

Power-failure deceleration time 2

0 to 3600/ 360s, 9999

0.1/0.01s

9999

43

266

Power failure deceleration time
switchover frequency

0 to 400Hz

0.01Hz

60Hz

43

267

Terminal 4 input selection

0, 1, 2

1

0

35

268

Monitor decimal digits selection

0, 1, 9999

1

9999

32

269

Parameter for manufacturer setting. Do not set.

299

Rotation direction detection selection at
restarting

0, 1, 9999

1

9999

33

RS

-4

8

5 c

o

mmu

ni

ca

tio

n

331

RS-485 communication station

0 to 31(0 to 247)

1

0

38

332

RS-485 communication speed

3, 6, 12, 24, 48, 96, 192,
384

1

96

38

333

RS-485 communication stop bit length

0, 1, 10, 11

1

1

38

334

RS-485 communication parity check
selection

0, 1, 2

1

2

38

335

RS-485 communication number of
retries

0 to 10, 9999

1

1

38

336

RS-485 communication check time
interval

0, 0.1 to 999.8s, 9999

0.1s

0s

38

337

RS-485 communication waiting time
setting

0 to 150ms, 9999

1

9999

38

338

Communication operation command
source

0, 1

1

0

44

339

Communication speed command source

0, 1, 2

1

0

44

340

Communication startup mode selection

0, 1, 2, 10, 12

1

0

37

341

RS-485 communication CR/LF selection

0, 1, 2

1

1

38

342

Communication EEPROM write selection 0, 1

1

0

38

343

Communication error count

1

0

38

R

em

ot

e ou

tput

495

Remote output selection

0, 1

1

0

44

496

Remote output data 1

0 to 4095

1

0

44

497

Remote output data 2

0 to 4095

1

0

44

M

ai

nt

en

anc

e

503

Maintenance timer

0 (1 to 9998)

1

0

44

504

Maintenance timer alarm output set time

0 to 9998, 9999

1

9999

44

C

om

m

u

ni

cat

ion

549

Protocol selection

0, 1

1

0

38

550

NET mode operation command source
selection

0, 1, 9999

1

9999

44

551

PU mode operation command source
selection

1, 2

1

2

44

Cu

rr

e

nt

av

er

a

ge

m

oni

to

r

555

Current average time

0.1 to 1.0s

0.1s

1s

44

556

Data output mask time

0.0 to 20.0s

0.1s

0s

44

557

Current average value monitor signal
output reference current

0 to 500/0 to 3600A

*1

0.01/0.1A

*1

Rated inverter

current

44

563

Energization time carrying-over times

0 to 65535

1

0

32

564

Operating time carrying-over times

0 to 65535

1

0

32

571

Holding time at a start

0.0 to 10.0s, 9999

0.1s

9999

29

PID

co

nt

ro

l

575

Output interruption detection time

0 to 3600s, 9999

0.1s

1s

39

576

Output interruption detection level

0 to 400Hz

0.01Hz

0Hz

39

577

Output interruption release level

900 to 1100%

0.1%

1000%

39

611

Acceleration time at a restart

0 to 3600s, 9999

0.1s

5/15s

*1

33

*1

Differ according to capacities. (55K or less/75K or more)

Function

Parameters

Name

Setting Range

Increments

Initial Value

Refer to

page

Advertising