Features

Standard

Specifications

Outline

Dimension

Drawings

Operation

Panel

Protective

Functions

Options

Instructions

Motor

Compatibility

W

arranty

Inquiry

Peripheral Devices

Why energy

savings?

Te

rminal Connection

Diagram

Te

rminal Specification

Explanation

Parameter

List

Explanations

of

Parameters

64

Item

FR-F500 (L)

FR-F700

Changed/cleared

functions

Simple mode parameters 61

Simple mode parameters 15

Pr. 0 Torque boost initial value
11K to 55K: 2%

Pr. 0 Torque boost initial value
11K to 37K: 2%, 45K, 55K: 1.5%
(When the torque boost value of the FR-F500 series
used was the initial value, it is not necessary to change
the torque boost value from the initial value when
replacing with the FR-F700 series.)

User group 1 (16), user group 2 (16)
(Pr. 160, Pr. 173 to Pr. 175)

User group (16) only
Setting methods were partially changed
(Pr. 160, Pr. 172 to Pr. 173)

User initial value setting (Pr. 199)

"User initial value setting" (Pr. 199) was cleared
Substitutable with the copy function of the operation
panel (FR-DU07)

DC injection brake function with terminal (X13 signal)
(Pr. 11 setting value 8888, Pr. 180 to Pr. 186 setting
value 13)

DC injection brake function with terminal was cleared
Start in reverse rotation is possible with flying start
function (frequency search of automatic restart after
instantaneous power failure function)

Long wiring mode
(Pr. 240 setting 10, 11)

Setting is not necessary
(Pr. 240 settings "10" and "11" were cleared)

Intelligent optimum acceleration/deceleration
(Pr. 60 setting "3" and Pr. 61 to Pr. 63)

Function was cleared
For deceleration time, overvoltage alarm can be avoided
with regeneration avoidance function (Pr. 882 to Pr. 885).

Automatic torque boost
(Pr. 38, Pr. 39)

Automatic torque boost was cleared because of addition
of "Simple magnetic flux vector" (Pr. 80)

Terminal block

Removable terminal block

Removable terminal block
Priority compatibility (Terminal block of the F500 can be
mounted)

PU

FR-PU04, DU04

FR-DU07
FR-DU04 unavailable (Partly restricted when the FR-
PU04 is used.)

Plug-in option

Dedicated plug-in option (not compatible)

Computer link, relay output option
FR-A5NR

Built into the inverter
(RS-485 terminals, relay output 2 points)

Three boards can be mounted

One board can be mounted

Installation size

FR-F720-0.75K, 2.2K, 3.7K, 7.5K, 18.5K, 22K, 37K, 45K,
FR-F740-0.75K to 3.7K, 7.5K, 22K, 37K to 55K are compatible in mounting dimensions
For other capacities, an optional intercompatibility attachment (FR-AAT) is necessary.

Main Differences and Compatibilities with the FR-F500(L) Series