Buzzer control of the operation panel, Pu contrast adjustment, Parameter clear, parameter copy – MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual

Page 45: Adjustment of terminal fm and am (calibration), 989, cl, allc, er.cl, pcpy

Advertising
background image

Features

Standard

Specifications

Outline

Dimension

Drawings

Operation

Panel

Protective

Functions

Options

Instructions

Motor

Compatibility

W

arranty

Inquiry

Peripheral Devices

Why energy

savings?

Te

rminal Connection

Diagram

Te

rminal Specification

Explanation

Parameter

List

Explanations

of

Parameters

46

indicates simple mode parameters and

indicates extended parameters. When setting parameters, refer to the instruction manual (applied) and understand instructions.

Pr.

Pr.

⋅ The following gives the items which can be monitored by the

cumulative saving power monitor (Pr. 52 = "51").
(The cumulative power monitor data digit can be shifted to the
right by the number set in Pr. 891 Cumulative power monitor digit
shifted times
.)

* The increments vary according to the inverter capacity. (55K or less/75K or

more)

The operation panel and parameter unit can be used to calibrate
the full scales of the terminals FM and AM.

(1) FM terminal calibration (C0(Pr.900))

⋅ The terminal FM is preset to output pulses. By setting the

Calibraton parameter C0 (Pr. 900), the meter connected to the
inverter can be calibrated by parameter setting without use
of a calibration resistor.

⋅ Using the pulse train output of the terminal FM, a digital

display can be provided by a digital counter. The monitor
value is 1440 pulses/s output at the full-scale value of Pr. 54
FM terminal function selection
.

*1 Not needed when the operation panel (FR-DU07) or parameter unit (FR-

PU04) is used for calibration.
Used when calibration must be made near the frequency meter for such a
reason as a remote frequency meter.
However, the frequency meter needle may not deflect to full-scale if the
calibration resistor is connected. In this case, use this resistor and
operation panel or parameter unit together.

(2) AM terminal calibration (C1(Pr.901))

⋅ The AM terminal is factory-set to output 10VDC in the full-

scale state of each monitor item. By setting the calibration
parameter C1 (Pr. 901)
, the ratio (gain) of the output voltage
can be adjusted to the meter scale. Note that the maximum
output voltage is 10VDC.

You can make the buzzer "beep" when you press key of the
operation panel (FR-DU07) and parameter unit (FR-PU04).

Contrast adjustment of the LCD of the parameter unit (FR-
PU04) can be performed.
Decreasing the setting value makes contrast light.

Set “1” in Pr.CL Parameter clear to initialize all parameters.
(Calibration parameters are not cleared.)*
Set “1” in ALLC All parameter clear to initialize all parameters. *
Set “1” in Er.CL Alarm history clear to clear alarm history. *
Parameter settings can be copied to multiple inverters by using
PCPY.

When parameters are copied to the 75K or more inverter from
the 55K or less inverter or vice versa, an

alarm appears on

the operation panel.
For the parameters whose setting range differ, set

Pr.989

as

below after reset.

* Parameters are not cleared when "1" is set in Pr.77 Parameter write selection.

Energy

Saving

Monitor

Item

Description and Formula

Increments

Power
saving
amount

Power saving is added up per hour.

Σ (Power saving × t)

0.01kWh/

0.1kWh*

Power
saving
amount
charge

Power saving amount represented in terms of
charge
Power saving amount

× Pr. 896

0.01/0.1*

Annual
power
saving
amount

Estimated value of annual power saving amount

Ч 24 Ч 365 Ч

0.01kWh/

0.1kWh*

Annual
power
saving
amount
charge

Annual power saving amount represented in
terms of charge
Annual power saving amount

× Pr. 896

0.01/0.1*

Adjustment of terminal FM
and AM (calibration)

C0(Pr.900) FM terminal calibration

C1(Pr.901) AM terminal calibration

C2(902) to C7(905)

Refer to the section about Pr. 125, Pr. 126

989

Parameter for manufacturer setting. Do not set.

Power saving amount

Operation time during

power saving totalization

Pr.899

100

Pr.

C0(900), C1(901)

8VDC

T2

T1

Pulse width T1: Adjust using calibration parameter C0
Pulse cycle T2: Set with Pr. 55 (frequency monitor)

Set with Pr.56 (current monitor)

(Digital indicator)

(-)

1440 pulse/s(+)

FM

SD

Indicator
1mA full-scale
analog meter

(+)

1mA

FM

SD

Calibration

resistor

*1

(-)

Pr.

Pr.

Buzzer control of the operation panel

Pr.990 PU buzzer control

Pr.990 Setting

Description

0

Without buzzer

1(initial value)

With buzzer

PU contrast adjustment

Pr.991 PU contrast adjustment

Pr.991 Setting

Description

0 to 63

0 : Light

63 : Dark

Parameter clear, parameter copy

Pr.989 Parameter copy alarm release
Pr.CL Parameter clear

ALLC All parameter clear

Er.CL Alarm history clear

PCPY Parameter copy

55K or less

75K or more

Pr.989

setting

10

100

PCPY

Setting

Description

0

Cancel

1

Copy the source parameters in the operation panel.

2

Write the parameters copied to the operation panel to the
destination inverter.

3

Verify parameters in the inverter and operation panel.

Pr.

990

Pr.

991

Pr.

989, CL, ALLC, Er.CL, PCPY