Features, Adjustable 5 points v/f, Upgrade of the renown optimum excitation control – MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual

Page 2: The effect of energy savings is obvious, Best match, Enhanced pid function, Restart after instantaneous power failure function, Flying start, Regeneration avoidance function, Commercial power-supply switchover sequence

Advertising
background image

Features

Standard
Specifications

Outline Dimension
Drawings

Terminal Connection
Diagram
Terminal Specification
Explanation

Explanation of the
Operation Panel
(FR-DU07)

Parameter List

Explanations of
Parameters

Protective Functions

Option and

Peripheral Devices

Precautions for
Operation/Selection
Precautions for Peripheral
Device Selection

Application to Motor

Warranty

Main differences and
compatibilities with
the FR-F500(L) series

International FA center

Connection with
Peripheral Devices
Why can the inverter
save energy?

1

5

7

9

16

19

21

28

47

49

59

63

64

65

66

(1)

Adjustable

5 points

V/F

2

1

Evolution of the inverter for fan and pump applications, energy savings for buildings and factories as a whole

Evolution of the inverter for fan and pump applications, energy savings for buildings and factories as a whole

[Ex. of Blower Operation Characteristics]

[Ratio of Motor Power Consumption during Acc./Dec.]

•Achieved a higher level of energy savings during acc./dec. to say

nothing of during constant speed.

FR-F700

Conventional model

(FR-F500)

Motor Lord Torque (%)

(1)

Upgrade of the renown Optimum Excitation Control!!

•The effect of energy savings can be confirmed using the

operation panel, output terminal (FM, AM terminal) and
via networks with the newly developed energy saving
monitor.

(2)

The effect of energy savings is obvious

Ex. of Power Savings
Monitor Display

[Energy Saving Monitor List]

Power saving monitor (kW)

Power saving rate (%)

Power saving amount (kWh)

Power saving amount charge ($)

Power saving average value (kW)

Power saving rate average value (%)

Power saving charge average value ($)

Annual power saving amount (kWh)

Annual power saving amount charge ($)

0

10

20

30

40

50

100

90

M

O

RE

SAVIN

G

S

!

Driving of the Mitsubishi 400V 4 poles
45kW motors comparison

12%

Commercial
power
operation

Frequency (Hz)

V/F control

0

10

20

30

40

50

60

20

40

60

80

100

Optimum

excitation

control

6%

Power Consumption (%)

Power Consumption Ratio (%)

A

Photo:FR-F740-5.5K

RS-485 terminal

Combed shaped wiring cover

Removable terminal block

Easy operation
with the setting
dial of the
operation panel

Built-in

EMC filter

AU/PTC

switchover switch

Connector

with/without

EMC filter

RS-485 communication is

possible with PU connector

Easy replacement with

the cooling fan cassette!!

E

G

C

H

A

B

D

F

BEST

MATCH

•Possible to set the torque

pattern that is optimum for the
machine's characteristic

•Possible to expect even more

energy savings with optimum
excitation control and optimum
V/F pattern working together

0

V/F5

V/F4

V/F3

V/F2

V/F1

Voltage

Base

Frequency

V/F Characteristic

Torque
characteristic
curves

V/F
pattern

Frequency

Base

Frequency

Vo

ltage

(2)

Enhanced PID function

•Energy savings in low speed region ... PID shutoff (sleep control) function
•Shorter PID startup time ... PID automatic switchover function
•Monitor of set point/measured value/deviation possible ... PID monitor
•Convenient for HVAC usage ... forward/reverse operation switchover

is simple with an external signal

•Corresponds to a wide range of detectors ... set point and measured value

for PID input can either be voltage (0 to 5V/0 to 10 V) or current (4 to 20mA)

(3)

Adoption of the original operation continuation

at instantaneous power failure function

•Operation continues without

the motor coasting when an
instantaneous power failure
occurred in fan and blower
applications.

*The inverter may trip and the motor may

coast depending on the load condition.

IPF

Input
Power Supply

Output
Frequency

Deceleration

Reacceleration

When power is restored during deceleration

•Restart can be made without stopping the

motor when the motor is coasting due to an
instantaneous power failure.

(4)

Restart after instantaneous

power failure function

•Smoothly restarts a motor that is rotating even in

the opposite direction due to the windmill effect.

(5)

Flying start

•Possible to avoid regeneration overvoltage alarm by

automatically increasing the frequency and continue
operation if the fan happens to rotate faster due to
the effect of another fan in the same duct.

(6)

Regeneration avoidance function

•Switchover to commercial power-supply operation is

simple using R1 and S1 terminals of the control circuit
and commercial power-supply switchover sequence.

(8)

Commercial power-supply

switchover sequence

•Protection of the motor can be certain since the

built-in PTC of the motor can be input directly in
addition to the electronic thermal relay function.

PTC thermistor input…Positive Temperature Coefficient Thermistor

(7)

PTC thermistor input

B

•Adoption of newly developed long life cooling fan

(design life of 10 years*

1

)

Longer operating life is further enhanced with the use of ON/OFF control of cooling fan.

•Adoption of long life capacitor

(design life of 10 years*

1, 2

)

A capacitor with specification of 5000 hours at 105˚C ambient temperature is adapted.

*1 Ambient temperature: yearly average 40˚C (free from corrosive gas, flammable gas, oil mist, dust and dirt)

Since the design life is a calculated value, it is not a guaranteed value.

*2 Output current: 80% of the rated current of Mitsubishi standard 4P motor

(1)

Operating life of parts are further lengthened

•Degrees of deterioration of main circuit capacitor, control circuit

capacitor or inrush current limit circuit can be diagnosed by monitor.

•Trouble can be avoided with the self-diagnostic alarms* that is

output when the life span is near.

*Any of alarm for main circuit capacitor, control circuit capacitor, inrush current limit

circuit and cooling fan can be output.

(2)

State of the art longevity diagnostic method

•Maintenance timer output function can also inform of

maintenance time for peripheral equipments.

•Average output current value and maintenance timer value are output as pulses.

(3)

Maintenance timer

(4)

Update is also easy

¥

When exchanging the inverter, the control

circuit terminals can be exchanged.
The removable terminal block of the FR-
F500 series can be used.

(The terminal block of the FR-F700 series is compatible with
that of the FR-F500 series.
Note that some functions of the FR-F700 series are restricted
when using the terminal block of the FR-F500 series.)

Removable terminal block

A

C

D

¥

Wiring cover can be reinstalled after wiring.

(200V class 22K or less, 400V class 30K or less)

Wiring is easy with the combed shaped wiring cover

¥

Parameter setting for multiple inverters is simple by

copy with the operation panel.

Possible to copy parameters with operation panel

(5)

Improved workability

¥

The installation position of the cooling fan is in the

upper portion of the inverter.
Fan replacement is easily done without having to
remove the main circuit wires.

Easy replacement of cooling fan

¥

Alarm history (alarm details and frequency, current, voltage

and cumulative energization time at time of alarm
occurrence) can be displayed on the operation panel and
the cause of a trouble can be checked.(up to 8 past alarms)

Alarm history

FR-F500 series

FR-F700 series

RELIABLE

EASY

I

I

Advertising