Protective functions – MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual

Page 46

Advertising
background image

47

When an alarm occurs in the inverter, the protective function is activated bringing the inverter to an alarm stop and the PU
display automatically changes to any of the following error (alarm) indications.

Function Name

Description

Indication

E

rro

r me

ss

ag

e

*2

Operation panel lock

Appears when operation is tried during operation panel lock.

Parameter write error

Appears when an error occurs at parameter writing.

Copy operation error

Appears when an error occurs at parameter copying.

Error

Appears when the RES signal is on or the PU and inverter can not make normal

communication.

Wa

rn

in

gs

*3

Stall Prevention

(overcurrent)

Appears during overcurrent stall prevention.

Stall prevention

(overvoltage)

Appears during overvoltage stall prevention

Appears while the regeneration avoidance function is activated.

Regenerative brake

prealarm

Appears if the regenerative brake duty reaches or exceeds 85% of the

Pr. 70

"special

regenerative brake duty" value. If the regenerative brake duty reaches 100%, a

regenerative overvoltage (E. OV_) occurs.

(displayed only for the 75K or more)

Electronic thermal relay

function prealarm

Appears when the electronic thermal O/L relay has reached 85% of the specified

value.

PU Stop

Appears when

on the operation panel was pressed during external operation.

Maintenance signal output

Appears when the cumulative energization time has exceeded the maintenance

output timer set value.

Parameter copy

Appears when parameters are copied between models with capacities of 55K or

less and 75K or more.

Mi

n

or

fa

u

lt

*4

Fan fault

Appears when the cooling fan remains stopped when operation is required or when the speed

has decreased.

Ma

jo

r fa

ilu

re

s

*5

Overcurrent shut-off during

acceleration

Appears when an overcurrent occurred during acceleration.

Overcurrent shut-off during

constant speed

Appears when an overcurrent occurred during constant speed operation.

Overcurrent shut-off during

deceleration or stop

Appears when an overcurrent occurred during deceleration and at a stop.

Regenerative overvoltage

shutoff during acceleration

Appears when an overvoltage occurred during acceleration.

Regenerative overvoltage

shut-off during constant

speed

Appears when an overvoltage occurred during constant speed operation.

Regenerative overvoltage shut-

off during deceleration or stop

Appears when an overvoltage occurred during deceleration and at a stop.

Inverter overload shut-off

(electronic thermal relay

function)

*1

Appears when the electronic thermal relay function for inverter element protection

was activated.

Motor overload shut-off

(electronic thermal relay

function)

*1

Appears when the electronic thermal relay function for motor protection was

activated.

Fin overheat

Appears when the heatsink overheated.

Instantaneous power failure

protection

Appears when an instantaneous power failure occurred at an input power supply.

Undervoltage protection

Appears when the main circuit DC voltage became low.

Input phase failure

Appears if one of the three phases on the inverter input side opened.

Stall prevention

Appears when the output frequency drops to 0.5Hz as a result of deceleration due to

the excess motor load.

Output side earth (ground)

fault overcurrent protection

Appears when an earth (ground) fault occurred on the inverter's output side.

Output phase failure

protection

Appears if one of the three phases on the inverter output side opened.

External thermal relay

operation

*6

Appears when the external thermal relay connected to the terminal OH operated.

PTC thermistor operation

Appears when the motor overheat status is detected for 10s or more by the external

PTC thermistor input connected to the terminal AU.

Option alarm

Appears when an alarm occurred in the option card or an AC power supply is

connected to the R/L1, S/L2, T/L3 when the high power factor converter connection

is set.

Option slot alarm

Appears when a communication error occurred in the communication option.

Option alarm

Appears when a functional error occurred in the plug-in option.

Parameter storage devide

alarm

Appears when operation of the element where parameters are stored became

abnormal. (control circuit board)

to

to

Protective Functions