Stand-alone option

Name (type)

Specifications, Structure, etc.

Intercompatibility
attachment
FR-AAT
FR-A5AT

FR-F500 series intercompatibility attachment

The FR-F700 series inverter can be installed using installation holes of the conventional FR-F500 series with this attachment.This attachment is use-
ful for replacing the conventional model with the FR-F700 series.
Since the installation size of the 400V class 0.75K to 3.7K, 7.5K, 22K, 37K to 55K are the same, an intercompatibility attachment is not necessary
* The depth increases after installation of the inverter when the attachment is used.

FR-A100E and FR-A200E series installation intercompatibility attachment

The FR-F700 series inverter can be installed using installation holes of the conventional FR-A100E and FR-A200E series with this attachment. This
attachment is useful for replacing the conventional model with the FR-F700 series.
* The depth increases after installation of the inverter when the attachment is used

AC reactor
(for power coordination)
FR-HAL-(H)

K

Outline dimension

DC reactor
(for power coordination)
FR-HEL-(H)

K

Outline dimension

Inverter

FR-AAT

12

Type

Applied Inverter

FR-AAT22

FR-F740-5.5K

FR-AAT24

FR-F740-15K, 18.5K

FR-AAT27

FR-F740-30K

Inverter

FR-A5AT

12

Type

Applied Inverter

FR-A5AT02

FR-F740-0.75K to 3.7K

FR-A5AT03

FR-F740-5.5K to 11K

FR-A5AT04

FR-F740-15K to 22K

FR-A5AT05

FR-F740-45K, 55K

(Unit: mm)

Type

W

D

H

Mass

(kg)

Type

W

D

H

Mass

(kg)

2
0
0

V

0.4K

104

72

99

0.6

4
0
0

V

H0.4K

135

59.6

115

1.5

0.75K

104

74

99

0.8

H0.75K

135

59.6

115

1.5

1.5K

104

77

99

1.1

H1.5K

135

59.6

115

1.5

2.2K

115

77

115

1.5

H2.2K

135

59.6

115

1.5

3.7K

115

83

115

2.2

H3.7K

135

70.6

115

2.5

5.5K

115

83

115

2.3

H5.5K

160

72

142

3.5

7.5K

130

100

135

4.2

H7.5K

160

91

142

5.0

11K

160

111

164

5.2

H11K

160

91

146

6.0

15K

160

126

167

7.0

H15K

220

105

195

9.0

18.5K

160

175

128

7.1

H18.5K

220

170

215

9.0

22K

185

158

150

9.0

H22K

220

170

215

9.5

30K

185

168

150

9.7

H30K

220

170

215

11

37K

210

174

175

12.9

H37K

220

170

214

12.5

45K

210

191

175

16.4

H45K

280

165

245

15

55K

210

201

175

17.4

H55K

280

170

245

18

H75K

205

208

170

20

(Note) 1. Make selection according to the applied

motor capacity. (When the inverter
capacity is larger than the motor
capacity, make selection according to the
motor capacity)

2. Power factor improving reactor (FR-BAL)

can be used.
Power factor improving effect
FR-BAL : approx. 90%
FR-HAL : approx. 88%

H

W

Less than D

(Unit: mm)

Type

W

D

H

Mass

(kg)

Type

W

D

H

Mass

(kg)

2
0
0

V

0.4K

70

61

71

0.4

4
0
0

V

H0.4K

90

60

78

0.6

0.75K

85

61

81

0.5

H0.75K

66

70

100

0.8

1.5K

85

70

81

0.8

H1.5K

66

80

100

1

2.2K

85

70

81

0.9

H2.2K

76

80

110

1.3

3.7K

77

82

92

1.5

H3.7K

86

95

120

2.3

5.5K

77

92

92

1.9

H5.5K

96

100

128

3

7.5K

86

98

113

2.5

H7.5K

96

105

128

3.5

11K

105

112

133

3.3

H11K

105

110

137

4.5

15K

105

115

133

4.1

H15K

105

125

152

5

18.5K

105

165

93

4.7

H18.5K

114

120

162

5

22K

105

175

93

5.6

H22K

133

120

178

6

30K

114

200

100

7.8

H30K

133

120

178

6.5

37K

133

195

117

10

H37K

133

155

187

8.5

45K

133

205

117

11

H45K

133

170

187

10

55K

153

209

132

12.6

H55K

152

170

206

11.5

(Note) 1.Be sure to remove the jumper across

terminals P/+ - P1 of the inverter. (A
failure to do so will produce no power
factor improving effect)

2. The wiring length between the reactor and

inverter should be within 5m.

3. The size of the cables used should be equal

to or larger than that of the power supply
cables (R/L1, S/L2, T/L3).

4. Make selection according to the motor

capacity.
(When the inverter capacity is larger than
the motor capacity, make selection
according to the motor capacity)

5. Power factor improving reactor (FR-BEL)

can be used.
Power factor improving effect
FR-BEL : approx. 95%
FR-HEL : approx. 93%

H

W

Less than D

Advertising