Marathon Monitors Inc.

AACC 2000 Carbon Nov. 1, 1997

25

Button or

indicator

Name

Explanation

OP1

Output 1

When lit, it indicates that the output installed in
module position 1 is on. This is normally the
heating output on a temperature controller.

OP2

Output 2

When lit, it indicates that the output installed in
module position 2 is on. This is normally the
cooling output on a temperature controller.

SP2

Setpoint 2

When lit, this indicates that setpoint 2, (or a
setpoint 3-16) has been selected.

REM

Remote setpoint

When lit, this indicates that a remote setpoint
input has been selected.

‘REM’ will also flash when communications is
active.

Auto/Manual

button

When pressed, this toggles between automatic
and manual mode:

If the controller is in automatic mode the

AUTO light will be lit.

If the controller is in manual mode, the MAN

light will be lit.

The Auto/Manual button can be disabled in
configuration level.

Run/Hold button

Press once to start an automatic Probe care

cycle

This RUN light indicates when ever a probe

care function is in progress

Page button

Press to select a new list of parameters.

Scroll button

Press to select a new parameter in a list.

Down button

Press to decrease a value in the lower readout.

Up button

Press to increase a value in lower readout.

Figure 2-3 Controller buttons and indicators