Sequence of component wiring, Ds2100 user's manual (preliminary), 6 sequence of component wiring recommendations – Moog DS2100 User Manual

Page 31

Advertising
background image

SECTION 3: WIRING AND INSTALLATION

DS2100 User's Manual (Preliminary)

PAGE 3-25

3.6 Sequence of Component Wiring Recommendations

The following sequence for wiring is a recommendation. Individual wiring steps are denoted by a box character, which
can be used as an installation check off list.

The terminal block layout on all power supplies and servo-drives has been designed to isolate low voltage from high
voltage circuits. Cabinet conduits should be arranged to maintain this physical separation.

a) Power Circuit Wiring

q

Wire a 24V Logic Supply to the drive (Required on

mA size drives). Fit a suitable EMC filter on the 24V logic

Supply and fuse.

q

Wire a.c. mains input to a user supplied fuses. Make a secure and reliable connection between the chassis of the
equipment and Earth.

q

Fit a suitable EMC Mains Line Filter after the User supplied fuses and contactor.

q

Wire a.c. mains from the user-supplied contactor to the power input poles of the DS2100.

b) Servo-drive Wiring

q

Plug in Axis I/O cable to J2 and connect other end to user I/O equipment.

q

Plug in resolver cable at J5 (or Encoder Cable to J4).

q

Connect appropriate communications cabling (RS232 at J1, and/or Field Bus

c) Motor Wiring

q

Repeat the steps listed in this Section for each motor in the system.

q

Plug in and screw tight resolver/encoder cable to motor position connector.

q

Plug in and screw tight motor power cable to motor power connector. Also connect the brake terminations at J2D
(if provided).

q

Connect motor power cable to appropriate drive power terminals.

Advertising