Paralleling through the dc bus, Ds2100 user's manual (preliminary), 1 m a size dc bus inter-connection – Moog DS2100 User Manual

Page 40

Advertising
background image

DS2100 User's Manual (Preliminary)

SECTION 3: WIRING AND INSTALLATION

PAGE 3-34

3.9 Paralleling DS2100 Units through the D.C. Bus

DS2100 units can be paralleled via the D.C. Bus, in order to share regeneration power.

3.9.1

mA Size DC Bus Inter-connection

Tie screen to chassis via
EMC bracket. See Section 2

L1 L2 L3 PE
(J6.4)(J6.5)(J6.6) Stud

Connector J6

DC- DC+
(J6.1)(J6.2)

DS2100 mA

L1 L2 L3 PE

(J6.4)(J6.5)(J6.6) Stud

DC- DC+

(J6.1) (J6.2)

DS2100 mA

a.c. Mains

L1

L2

L3

Protective

Earth

Connector J6

Figure 3.21 Size

mA DC Bus Inter-connection

-

Fixed connector: 12 pins, male connector

-

Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-7.62)

-

mA size wiring: cable 14 AWG (2.1 mm

2

). Wire stripping: 7 mm.

-

PE Stud wiring: cable 6 AWG (13mm

2

)

-

Tightening torque: 0.5Nm.

To comply with the EMC Directive, the DC Bus cable must be
shielded and the shield must be connected to the housing with a 360

o

connection at both ends.

Required for

CE-Compliance

CAUTION – To connect drives through the DC bus, please contact
Moog application engineering for advice.