3.7.1 AC Mains Power Source Connection

3.7.1.1 Size

mA

EMC Filter,

Fuses etc.

See

Section 2

Installation

4 5 6

L1 L2 L3

Connector J6

mA

4 5 6

L1 L2 L3

Connector J6

mA

PE

Stud

PE

Stud

a.c. Mains

L1

L2

L3

Protective

Earth

Figure 3.15

mA AC Mains Input Connection

-

Fixed connector: 12 pins, male connector

-

Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-7.62)

-

mA size wiring: cable 14 AWG (2.1 mm

2

). Wire stripping: 7 mm.

-

PE Stud wiring: cable 6 AWG (13mm

2

)

-

Tightening torque: 0.5Nm.

Pos.

Name

Function

J6.4

L1

Phase "L1", three-phase voltage input 230/460Vac

±10%

J6.5

L2

Phase "L2", ", three-phase voltage input 230/460Vac

±10%

J6.6

L3

Phase "L3", ", three-phase voltage input 230/460Vac

±10%

PE

PE

Protective Earth Stud on Chassis

Table 3.3 J6 AC Mains Power connector,